PubMed HealthSearch

PubMed · 8587047

Determination of the mechanism for the decrease in zinc oxide surface area upon high-temperature drying.

Abstract

High-temperature drying is required to remove chemisorbed water from the zinc oxide surface. High-temperature drying of a very small particle size zinc oxide powder (median particle size approximately 23 nm) resulted in a substantial decrease in the surface area. The surface areas (BET analysis of 77 K nitrogen vapor adsorption data) of ZnO samples dried at 500 degrees C decreased continually as the drying time was increased. Although the surface area decrease was fastest during the first 5 h, a 64% decrease in surface area was found after 20 h. The decrease in surface area was not due to a collapse of pore structure. Comparison of nitrogen vapor adsorption and desorption isotherms as well as geometric calculations of surface area indicated that both the original and final particles were nonporous. X-ray diffractograms of the original powder and of powders dried at two temperatures were all identical. Thus, no change in crystal structure occurred as a result of drying at 500 degrees C. Atomic force microscopy provided substantial evidence that the surface area decrease was due to a shift in the particle size distribution to a larger mean size. It was verified using two different experiments that ZnO exhibited significant sublimation at 500 degrees C. It was concluded that the increase in particle size was due to a sublimation/condensation process that obeyed the Kelvin equation. The effect of ZnO particle size on the vapor pressure ratio in the Kelvin equation was modeled at 500 degrees C for several different assumed solid surface tensions. Drying conditions for ZnO were then selected which balanced maximum removal of chemisorbed water and minimum surface area decrease. Water vapor adsorption isotherms for ZnO at 25 degrees C were subsequently obtained. Differences in the isotherms resulting from the presence or absence of a chemisorption contribution could clearly be demonstrated.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D E Wurster, E Oh, J C Wang. 1995. Determination of the mechanism for the decrease in zinc oxide surface area upon high-temperature drying.. https://doi.org/10.1002/jps.2600841109

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Three-dimensional porous nano-hydroxyapatite@gelatin composite as efficient adsorbent for uranyl ion removal from low-level radioactive wastewater.

The contamination of water resources by uranyl (UO22+) ions poses significant environmental and health risks, requiring the development of efficient and sustainable remediation strategies. Adsorption-based techniques have emerged as promising approaches in the field of UO22+ removal, but the design of cost-effective, high-capacity, and environmentally friendly adsorbents remains challenging. In this study, a three-dimensional porous nano-hydroxyapatite@gelatin (nHAP@Ge) composite was synthesized through glutaraldehyde cross-linking, combining the structural stability of Ge with the high uranium affinity of nHAP. The optimized nHAP@Ge, with a nHAP:Ge mass ratio of 1:0.5, exhibited exceptional UO22+ removal efficiency (97 %), along with high adsorption capacity (364.03 mg/g). Systematic characterizations using scanning electron microscopy (SEM), thermogravimetric analysis (TGA), Fourier transform infrared (FT-IR) spectroscopy, and X-ray photoelectron spectroscopy (XPS) methods revealed that the porous structure and surface functional groups (-OH, Ca2+, and PO43-) of the material synergistically contributed to binding UO22+ species. Furthermore, the incorporation of nHAP into the Ge framework resulted in enhanced thermal stability while significantly improving the UO22+ adsorption performance. This work presents a scalable, eco-friendly, and recyclable strategy for the effective treatment of uranium-contaminated water, with potential applications in nuclear wastewater treatment and environmental remediation.

Adsorption

Heterobifunctional membranes by plasma induced graft polymerization as an artificial organ for penetration keratoprosthesis.

Highly biocompatible polymer membrane was developed for an artificial cornea in this surface modification study. Heterobifunctional silicone rubber membranes (hetero-SR) were prepared by grafting different functional polymers on each side of a silicone rubber membrane (SR). A novel type of bifunctional membrane was developed with the upper-side favoring cell attachment and growth, and the lower-side suppressing cell adhesion. The preparation of heterobifunctional membranes, characterization of polymer membrane surface properties such as ATR-FTIR and ESCA and contact angle, and biological analysis (in vitro and in vivo studies) were investigated in this work. Based on the biological analysis, the heterobifunctional membrane displays promising potential for use as an artificial cornea.

Adsorption

A new attenuated total reflectance Fourier transform infrared spectroscopy method for the study of proteins in solution.

An attenuated total reflectance Fourier transform infrared method has been developed that allows collection of spectra from proteins in solution. This method eliminates any structural perturbations induced by the internal reflection element (IRE), and thus the spectra reflect the solution conformation of the protein. A key feature of the method is subtraction of the signal from any protein adsorbed to the IRE. The advantages of this method include the small amount of sample required and the high sampling rate. Attenuated total reflectance (ATR)-Fourier transform infrared spectroscopy (FTIR) is more versatile than transmission FTIR because it is possible to collect spectra of nontransparent samples, to use samples of very low protein concentration (< or = 0.3 mg/ml), and to study proteins in the presence of strongly absorbing solutes (such as denaturants). The experimental procedures and data processing routines developed were evaluated by collecting spectra from a set of 13 proteins and evaluating their accuracy with a partial least-squares analysis. The relative mean and standard deviation errors for the basis set analysis were 6.3% for alpha-helix, 5.9% for beta-sheet/extended structure, and 4.4% for turn, which are similar to values from comparable analyses of transmission FTIR spectra. In addition, a detailed comparison between this solution ATR method and the hydrated thin-film ATR technique is presented.

Adsorption