[How effective is asymmetrical headgear in practical use?].

Abstract

The asymmetrical face bow with internal hinge was successfully employed in the treatment of all examined patients. It finds application as an individual appliance, in combination with removable appliances, and in conjunction with the fixed appliance technique. The major advantage of the face bow is that during a check-up visit, because it is already in place, it presents itself as a proven means for the treatment of asymmetries by adding a hinge on the side not to be distalized and by shortening the external arm on the same side. It is not necessary to employ a new, special face bow or even to change the orthodontic bands. In addition, in the case of an intermaxillary midline correction, no anchorage loss occurs. In the case of more extensive molar rotations, a pretreatment with a palatal archwire is recommended to rotate the molars. Because in 4% of the patients a cross bite or a cross bite tendency arises on the side distally treated, at the beginning of treatment the use of bands with attachments for palatal archwires should be considered. Relatively sizable distal forces in the range of 2:1 to 4:1 are exerted on the molar. This should be taken into account when selecting the forces of the external arm. It is recommended to apply on each of both sides a distal force of no more than 4 to 5 N. Decoupling of forces and movements through the internal hinge makes it possible for the practitioners to check the asymmetrical effect of the face bow by pulling out carefully the lingual archwire from the right or left tube. As long as the hinge still folds down, when the face bow is applied, the geometrics of the face bow should be altered. The following procedures can be recommended: 1. Further shortening of the already shortened arm; 2. outward bending of the long external arm; 3. use of an additional stop tube at the lingual archwire on the side that must be distalized. During the use of related low-pulls, the molars are subjected to diverse forces as a result of preferred sleeping positions, head bearings, and extensive friction, To avoid these non-calculable asymmetries, it is recommended to use gliding low-pulls. Because of the excellent results achieved throughout the use of the asymmetrical headgear with the lingual archwire, it can be recommended that it become a standard appliance in clinical practice.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Wichelhaus, F G Sander, E Inglezos. 1995. [How effective is asymmetrical headgear in practical use?].. https://doi.org/10.1007/bf02173159

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of excessive tibial torsion on the capacity of muscles to extend the hip and knee during single-limb stance.

Excessive tibial torsion, a rotational deformity about the long axis of the tibia, is common in patients with cerebral palsy who walk with a crouch gait. Previous research suggests that this deformity may contribute to crouch gait by reducing the capacity of soleus to extend the knee; however, the effects of excess external torsion on the capacity of other muscles to extend the stance limb during walking are unknown. A computer model of the musculoskeletal system was developed to simulate a range of tibial torsion deformities. A dynamic analysis was then performed to determine the effect of these deformities on the capacity of lower limb muscles to extend the hip and knee at body positions corresponding to the single-limb stance phase of a normal gait cycle. Analysis of the model confirmed that excessive external torsion reduces the extension capacity of soleus. In addition, our analysis revealed that several important muscles crossing the hip and knee are also adversely affected by excessive tibial torsion. With a tibial torsion deformity of 30 degrees , the capacities of soleus, posterior gluteus medius, and gluteus maximus to extend both the hip and knee were all reduced by over 10%. Since a tibial torsion deformity reduces the capacity of muscles to extend the hip and knee, it may be a significant contributor to crouch gait, especially when greater than 30 degrees from normal, and thus should be considered by clinicians when making treatment decisions.

Biomechanical Phenomena↗

Predicting the subject-specific primary stability of cementless implants during pre-operative planning: preliminary validation of subject-specific finite-element models.

Pre-operative planning help the surgeon in taking the proper clinical decision. The ultimate goal of this work is to develop numerical models that allow the surgeon to estimate the primary stability during the pre-operative planning session. The present study was aimed to validate finite-element (FE) models accounting for patient and prosthetic size and position as planned by the surgeon. For this purpose, the FE model of a cadaveric femur was generated starting from the CT scan and the anatomical position of a cementless stem derived by a skilled surgeon using a pre-operative CT-based planning simulation software. In-vitro experimental measurements were used as benchmark problem to validate the bone-implant relative micromotions predicted by the patient-specific FE model. A maximum torque in internal rotation of 11.4 Nm was applied to the proximal part of the hip stem. The error on the maximum predicted micromotion was 12% of the peak micromotion measured experimentally. The average error over the entire range of applied torques was only 7% of peak measurement. Hence, the present study confirms that it is possible to accurately predict the level of primary stability achieved for cementless stems using numerical models that account for patient specificity and surgical variability.

Biomechanical Phenomena↗

Experimental validation of intact and implanted distal femur finite element models.

Four finite element (FE) models of intact and distal femur of knee replacements were validated relative to measured bone strains. FE models of linear tetrahedrons were used. Femoral replacements with cemented stemless, cemented and noncemented femoral stems of the PFC Sigma Modular Knee System were analyzed. Bone strains were recorded at ten locations on the cortex. The magnitude of the FE bone strains corresponded to the mean measured strains, with an overall agreement of 10%. Linear regression between the FE and mean experimental strains produced slopes between 0.94 and 1.06 and R(2) values between 0.92 and 0.99. RSME values were less than 12%. The FE models were able to adequately replicate the mechanical behavior of distal femur reconstructions.

Biomechanical Phenomena↗