PubMed HealthSearch

PubMed · 8656137

Errors in ECG parameter estimation from standard leadsets.

Abstract

With the availability of low-cost, high-speed computers with (relatively) vast amounts of storage has come something of an explosion in the application of "quantitative electrocardiography." A search of the Medline medical reference database on the subject string "quantitative AND electrocardiography" reveals no less than 509 citations, suggesting that the term has gained widespread acceptance. However, while quantitative techniques are, in general, to be welcomed to clinical medicine and research, their use as a diagnostic or patient monitoring tool begs a careful examination of just what is being counted and how it is being linked to physiology. In this study, the authors focus on the use of standard electrocardiographic lead systems as the basis for quantitative patient evaluation and attempt to highlight some limitations in the ability to extract meaningful parameters with such a limited sampling of human thoracic electrical activity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R S MacLeod, R L Lux. 1995. Errors in ECG parameter estimation from standard leadsets.. https://doi.org/10.1016/s0022-0736(95)80033-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Predictors of long-term outcome after stent implantation in a saphenous vein graft.

Stenting of saphenous vein graft (SVG) lesions is associated with significant clinical events at late follow-up. We sought to determine predictors of clinical outcome after this procedure. One hundred twenty-eight balloon-expandable stents were implanted in the SVGs of 106 patients. Baseline clinical and angiographic characteristics were analyzed. All grafts, including those not stented, were scored for extent of disease involving the luminal surface of the graft, and for the presence of low profile lesions (< 50% graft stenosis) and/or high profile lesions (> or = 50% graft stenosis). The in-hospital success rate was 98.1%. Before discharge, no patient died, required bypass surgery, or had repeat angioplasty of the same graft. Follow-up was obtained on all the patients. At a median of 18 months, 15% had died, 17% had experienced myocardial infarction, 20% had required repeat bypass surgery, and 37% needed repeat angioplasty to either the same site or a different lesion. Event-free survival was recorded in only 44% of the patients. The cumulative Kaplan-Meier survival at 2.4 years was 78.7%. Using the Cox proportional hazards model, predictors of survival were the absence of a high profile lesion in any nonstented patent graft (p = 0.004), and the use of lipid-lowering agents at follow-up (p = 0.01). Stenting SVG lesions can be performed with a high degree of procedural success, but at long-term follow-up there is a high rate of cardiac events. The absence of a high profile lesion in any nonstented patent graft is the strongest predictor of survival.

Angioplasty, Balloon, Coronary

Mechanisms, management, and outcome of failure of delivery of coronary stents.

In a single-center experience, initial failure of attempted stent delivery was relatively infrequent (2.7%) but was associated with increased need for urgent coronary bypass surgery. Delivery failure was more likely with coiled stents and dislodgment from the delivery balloon was more likely with hand-mounted or radiolucent stents.

Angioplasty, Balloon, Coronary