Validation testing of the spacelabs PC2 ST-segment analyzer.

Abstract

OBJECTIVES: Recent studies have demonstrated that perioperative myocardial ischemia, detected by electrocardiography, is a risk factor for myocardial infarction. ST-segment analyzers and hemodynamic monitors may be useful for on-line detection in perioperative and critical care environments. However, independent performance and accuracy standards for these devices have not been established. Therefore, a testing protocol was developed using an electrocardiogram (ECG) simulator that allowed selectively altered ST-segment displacement, in a calibrated fashion over a wide range. DESIGN: Laboratory bench study. SETTING: Not applicable. PARTICIPANTS: Not applicable. INTERVENTIONS: Not applicable. MEASUREMENTS AND MAIN RESULTS: Custom digital ECG waveform templates were programmed for use with a commercially available ECG simulator (M311 ECG simulator; Fogg Systems, Inc., Aurora, CO). For each template, ST-segment morphology (horizontal elevation or depression, downsloping depression), QRS duration, and the presence or absence of a P wave were manipulated, resulting in seven different QRS shapes. Within each shape, the degree of ST-segment deviation was altered over a wide range. A PC2 Bedside Monitor (SpaceLabs Inc., Redmond, WA) was tested. One hundred forty-eight measurements of ST-segment deviation input from the simulator were made at each of two testing sessions. The first ST-segment value displayed by the analyzer was recorded, and the two measurements averaged for comparison. Placement of the J-point, J + 60 msec, and isoelectric reference points by the analyzer were evaluated. Simulator output was validated for accuracy and stability. Subtle errors in placement of the J-point marker were observed in all seven QRS shapes. These errors usually did not alter placement of the isoelectric marker before, but not exactly at the beginning of, the R-wave upstroke. Thus, ST-segment values returned by the monitor (J + 60 msec - isoelectric reference value) were unaffected. However, in two QRS shapes, the isoelectric point was displaced onto the upstroke of the R wave, resulting in erroneous ST-segment values. In one, the error may have been caused by the difference in QRS duration of that template (120 msec) relative to the fixed 115-msec interval from the J point used by the analyzer and was present in all points tested. In the second (normal QRS duration), the error was present in some, but not all points tested (4/21, 24%). All QRS shapes with proper placement of the isoelectric point returned ST-segment values within +/- 0.5 mm of expected, and 98% were within +/- 0.25 mm of expected. The mean difference between observed and expected ST-segment values for 100 measurements with normal QRS duration and proper isoelectric point placement was 0.08 mm +/- 0.07 mm (SD). CONCLUSIONS: The bench results suggest that visual confirmation of ST-segment analyzer values may be advisable in the clinical setting. Although most complexes with normal conduction and a P wave are likely to be accurately analyzed, those with prolonged QRS duration were problematic. The simulator protocol may be helpful in ensuring accuracy of ST-segment analyzers, especially in their early development stages.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M J London, L D Ahlstrom. 1995. Validation testing of the spacelabs PC2 ST-segment analyzer.. https://doi.org/10.1016/s1053-0770(05)80230-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Fermentation process tracking through enhanced spectral calibration modeling.

The FDA process analytical technology (PAT) initiative will materialize in a significant increase in the number of installations of spectroscopic instrumentation. However, to attain the greatest benefit from the data generated, there is a need for calibration procedures that extract the maximum information content. For example, in fermentation processes, the interpretation of the resulting spectra is challenging as a consequence of the large number of wavelengths recorded, the underlying correlation structure that is evident between the wavelengths and the impact of the measurement environment. Approaches to the development of calibration models have been based on the application of partial least squares (PLS) either to the full spectral signature or to a subset of wavelengths. This paper presents a new approach to calibration modeling that combines a wavelength selection procedure, spectral window selection (SWS), where windows of wavelengths are automatically selected which are subsequently used as the basis of the calibration model. However, due to the non-uniqueness of the windows selected when the algorithm is executed repeatedly, multiple models are constructed and these are then combined using stacking thereby increasing the robustness of the final calibration model. The methodology is applied to data generated during the monitoring of broth concentrations in an industrial fermentation process from on-line near-infrared (NIR) and mid-infrared (MIR) spectrometers. It is shown that the proposed calibration modeling procedure outperforms traditional calibration procedures, as well as enabling the identification of the critical regions of the spectra with regard to the fermentation process.

Calibration↗

Particle sizing with a fast polar nephelometer.

We reported previously the design of a polar nephelometer that uses a rotational confocal imaging setup to enable fast scanning of the scattering phase function within a field of view of 55 degrees . The full dynamic range of the detection system can be used by increasing the signal-to-noise ratio by means of averaging successive scans. The calibration of the angular response of the instrument is achieved by obtaining the transfer function of the optical detection system using Rayleigh scatterers. Accurate particle sizing of individual polystyrene spheres (ranging from 1.5 to 9 micro m in diameter) in aqueous suspension is achieved by maximizing a correlation coefficient between precalculated tables of Mie phase functions and data obtained from the polar nephelometer. Good correlation is achieved between experimental and theoretical data, proving the functioning of the instrument as a fast and convenient particle sizer.

Calibration↗

Online standard additions calibration of transient signals for inductively coupled plasma mass spectrometry.

An online standard additions calibration method for transient signals in ICPMS is demonstrated in which a small volume of standard is injected as a spike into the sample/carrier stream, overlaying the analyte peak. This technique provides the advantages of conventional standard additions but requires only a single sample run. The method corrects for matrix effects and is suitable for transient signals in which the severity of the matrix effect changes over the analyte peak. The method uses a peak-fitting program to determine the area of the underlying peak and is shown to be effective for the determination of trace metal concentrations in both a high ionic strength matrix and in a biological matrix (urine). Eight analytes with concentrations in the range of 0.82-233.2 mug L-1 in urine were simultaneously determined using a standard spiking solution of 75 mug L-1 injected through a 100-muL loop. The measured concentrations for analytes free of spectral interferences agreed with the certified values, and the precision achieved was comparable to that achieved by the certifying agency. Using a conventional cross-flow nebulizer and Scott-type spray chamber, the accuracy obtained for online standard additions calibration was within 2%, and the precision was within 5%.

Calibration↗