PubMed HealthSearch

PubMed · 871288

Effective temperature scale useful for hypo- and hyperbaric environments.

Abstract

Basic physics of man's heat exchange by radiation, convection, evaporation, and conduction through clothing is used to define and establish a Standard Effective Temperature Scale (SET), with which sensory and physiological responses of sedentary and active personnel can be related. The standard environment chosen is the Effective Temperature (ET) Scale, used by the American Society of Heating, Refrigerating and Air-Conditioning Engineers; namely, as the temperature of an isothermal enclosure at sea level with 50% rh and still air (0.1-0.15 m/s) in which a clothed (0.6 clo) sedentary subject would exchange the same total sensible and insensible heat as in the actual test environment. Mean skin temperature (Tsk) and skin wettedness (w) can be associated at sea level with thermal comfort and neutrality and with heat exchange. For hypo- and hyperbaric environments, thermal equivalence between SET and any test environment occurs when mean body temperature (Tb) for each is identical. Comprehensive data, developed for a 2-node model of human temperature regulation and of the associated partitional calorimetry, demonstrates the expected interaction between SET and the basic environmental and clothing factors over the barometric range 0.33 to 30 ATA.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y Nishi, A P Gagge. 1977. Effective temperature scale useful for hypo- and hyperbaric environments.. https://pubmed.ncbi.nlm.nih.gov/871288/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effects of separated flow on cotton dust sampling with a vertical elutriator.

The vertical elutriator used for cotton dust sampling was examined theoretically and experimentally to determine airflow patterns and particle transport. The theory of diverging channel flow predicts that a separated eddying flow will occur in the elutriator. This calculation disagrees with the laminar flow assumptions used to predict the size sampling characteristic or cutoff of the elutriator. Smoke injection tests verified random local velocity components and clearly showed that the flow is not uniformly upward and laminar. Particle transport tests indicated that unit density spheres as large as 27 micron can reach the sample on the elutriator filter.

Air Movements