PubMed HealthSearch

PubMed · 8792992

Decrease in internal jugular endothelin levels after carotid cross-clamping during human carotid revascularization procedures.

Abstract

Endothelin-1 (ETL-1), a peptide recently isolated from vascular endothelial cells, acts in cerebral arteries in vitro as a potent and long-lasting vasoconstrictor and has been implicated in the development of cerebral vasospasm. To ascertain whether this new vasoconstrictor has any effect on regulation of the cerebral circulation, we measured plasma ETL-1 concentrations in patients undergoing carotid revascularization and attempted to correlate the variations of venous and arterial plasma ETL-1 with the characteristics of the procedure, including cerebral vasospasm. We prospectively studied 11 patients undergoing a total of 14 carotid surgical revascularization procedures (12 endarterectomies, 2 polytetrafluoroethylene bypass grafts from the common to the internal carotid arteries). Before carotid cross-clamping, blood samples were drawn from the internal jugular vein and the healthy common carotid artery proximal to the occlusive lesion to be treated. After endarterectomy, blood samples were withdrawn from the internal, external, and common carotid arteries. After the release of the last clamp, a final aliquot of blood was withdrawn from the internal jugular vein. After plasma extraction on a C2-ethyl microcolumn, plasma endothelin-like immunoreactivity was measured by means of radioimmunoassay with a polyclonal antibody. In 9 of the 11 patients, internal jugular vein ETL-1 concentration decreased statistically significantly after carotid artery cross-clamping (4.2 +/- 1.4 pg/ml vs. 3.9 +/- 1.1 pg/ml; p < 0.05). In the 2 patients in whom ETL-1 levels failed to drop, a shunt was used during the procedure in 1, and the other was the only patient who had an ipsilateral ischemic postoperative stroke. The decrease in internal jugular vein ETL-1 concentration failed to correlate with any of the cross-clamping times. The level of arterial blood ETL-1 remained steady in the common carotid artery before and after cross-clamping (4.5 +/- 1.5 pg/ml vs. 4.6 +/- 0.9 pg/ml). A small, nonsignificant decrease in ETL-1 level was noted in the external and internal carotid arteries after cross-clamping. The decrease in internal jugular vein ETL-1 levels may in part reflect a compensatory response to carotid artery cross-clamping, which could limit the reduction of local cerebral blood flow.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Cacoub, F Koskas, S Timsit, G Maistre, A Gatel, J C Piette, P Godeau, A Carayon, E Kieffer. 1996. Decrease in internal jugular endothelin levels after carotid cross-clamping during human carotid revascularization procedures.. https://doi.org/10.1007/bf02001889

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Lipid concentration profile across the wall of pseudoatherosclerotic synthetic arterial prostheses using FTIR microspectroscopy.

FTIR microscopy is a versatile technique successfully used to probe the subcellular chemical composition of atherosclerostic arterial walls. To design new vascular substitutes that resist lipid uptake (the major cause of the phenomenon referred to as atherosclerosis-like), identifying and understanding lipid distribution within the pseudoatherosclerosed arterial prostheses is of prime importance. Until now, the amount of lipids present within arterial prostheses that had been explanted from either animals (during in vivo trials) or humans (after the failure of vascular grafts) or had been submitted to in vitro investigations could only be measured through the use of histological techniques or radioactive labeling methods. We present here a novel method to quantitatively measure the lipid concentration profile within the wall of arterial prostheses by means of Fourier transform infrared microspectroscopy. Essentially, prostheses are fixed in a 1% osmium tetraoxide aqueous solution under vacuum and radially cut with a 5-micron thickness with a microtome. The sections are then placed onto BaF2 windows and observed with a microscope attached to a FTIR spectrometer with a 30 microns x 50 microns sampling area. The lipid concentration profile is obtained by scanning the prosthesis wall from the inner to the outer surface and reporting the corresponding integrated absorbance between 2700 and 3100 cm(-1) against a calibration curve. The application of this technique constitutes the first quantitative measurement of the concentration of biological molecules within the wall of artificial arterial substitute.

Blood Vessel Prosthesis