PubMed Health⌕ Search

PubMed · 8829188

Secretin-induced plasma bicarbonate decrease as a simple indicator of exocrine pancreatic function.

Abstract

During a secretin-cerulein test for exocrine pancreatic function, venous acid-base analysis was performed before and 30 and 45 min after the intravenous injection of secretin (1 clinical unit/kg body weight). A decrease in plasma bicarbonate was observed in persons with normal exocrine pancreatic function as defined by normal bicarbonate and enzyme secretion in the secretin-cerulein test (n = 39). Bicarbonate values were 94.8 +/- 3.6% (mean +/- SD) of the initial concentration after 30 min and 92.9 +/- 3.9% after 45 min. In contrast, there was no statistically significant decrease in plasma bicarbonate in patients with global pancreatic exocrine deficiency (n = 15). In normal exocrine pancreatic function, the maximal plasma bicarbonate decrease was 2.17 +/- 1.12 mM (mean +/- SD; n = 39). In patients with global exocrine deficiency, however, a maximal plasma bicarbonate decrease of 0.54 +/- 0.68 mM (n = 15) was obtained. The difference was highly significant (p < 0.001). In patients with partial exocrine deficiency (isolated decrease in bicarbonate secretion or reduced excretion of a single enzyme), values were also significantly lower (1.44 +/- 1.40 mM; n = 14; p < 0.05). The maximal plasma bicarbonate decrease correlated with the bicarbonate secretion into the duodenal juice (r = 0.62, p < 0.001). If a maximal plasma bicarbonate decrease > or = 0.9 mM was considered normal, determination of plasma bicarbonate following secretin administration allowed us to detect the presence of global exocrine deficiency with a sensitivity of 87% and a specificity of 87%. The secretin-induced plasma bicarbonate decrease may therefore be used as a new simple tubeless test to evaluate exocrine pancreatic function.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Wettstein, D Häussinger. 1996. Secretin-induced plasma bicarbonate decrease as a simple indicator of exocrine pancreatic function.. https://doi.org/10.1097/00006676-199608000-00011

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The weighted walking test as an alternative method of assessing aerobic power.

The aim of the present study was to determine maximal oxygen uptake (VO2max) directly during uphill walking exercise and to compare these values with those achieved during running and cycling exercise. Forty untrained students (20 males and 20 females) took part in three exercise tests. The running test was performed on a horizontal treadmill and the speed was gradually increased by 0.3 m . s(-1) every 3 min. The walking test was conducted on a treadmill inclined at 12% (speed of 1.8 m . s(-1)). The load was further increased every 3 min by the addition of a mass of one-twentieth of the body mass of the participant (plastic containers filled with water and added to a backpack carried by the participant). During the bicycle ergometry test, the workload was increased by 20 W every 2 min. All tests were performed until volitional exhaustion. During all tests, oxygen uptake, minute ventilation, tidal volume, respiratory frequency, heart rate, hydrogen ion concentration, base excess, and blood lactate concentration were analysed. The Pearson correlation coefficients between the weighted walking test and the commonly applied running and bicycle ergometry tests indicate a strong association with the new test in evaluating maximal oxygen uptake. The negligible differences in VO2max between the three tests for the male participants (running: 61.0 ml . kg(-1) . min(-1); walking: 60.4 ml . kg(-1) . min(-1); cycling: 60.2 ml . kg(-1) . min(-1)), and the fact that the females achieved better results on the walking test than the cycle ergometer test (running: 45.0 ml . kg(-1) . min(-1); walking: 42.6 ml . kg(-1) . min(-1); cycling: 40.1 ml . kg(-1) . min(-1)), confirm the suitability of the new method for evaluating aerobic power. The weighted walking test could be useful in the assessment of aerobic power in individuals for whom running is not advised or is difficult. In addition, the new test allows for determination of VO2max on small treadmills with a limited speed regulator, such as those found in specialist physiotherapy and fitness centres.

Acid-Base Equilibrium↗

Mandatory protocol for treating adult patients with diabetic ketoacidosis decreases intensive care unit and hospital lengths of stay: results of a nonrandomized trial.

OBJECTIVE: To determine the effect of a mandatory protocol for treating diabetic ketoacidosis. DESIGN: Chart review of patients treated before and after protocol implementation. SETTING: University-affiliated U.S. public teaching hospital. PATIENTS: A total of 241 consecutive nonpregnant patients >18 yrs old admitted to a medical intensive care unit for diabetic ketoacidosis between January 2000 and January 2005. INTERVENTION: Implementation of a mandatory treatment protocol in May 2003. MEASUREMENTS: Intensive care unit and hospital lengths of stay, time to correction of anion gap and ketone clearance, and hypoglycemic episodes. RESULTS: Before protocol implementation, the mean +/- sd intensive care unit and hospital lengths of stay were 44 +/- 28 hrs and 91 +/- 73 hrs, respectively. After implementation, intensive care unit and hospital lengths of stay decreased 23% and 30%, to 34 +/- 18 hrs and 64 +/- 41 hrs, respectively (both p < .007). Time to anion gap closure and ketone clearance also decreased (both p < .05). No difference in the number of hypoglycemic episodes was observed. CONCLUSION: Implementing a mandatory protocol for treating adult patients with diabetic ketoacidosis decreases intensive care and hospital lengths of stay and time to anion gap closure and ketone clearance, without increasing the rate of hypoglycemia.

Acid-Base Equilibrium↗