Biosafety implications in sample introduction: module design characteristics for discrete-sample systems used in critical whole blood analyte testing environments.

Abstract

Systems designed for the measurement of pH/blood gases and expanded versions of these systems that include the ability to measure electrolytes or other related quantities, all incorporate one or more sampling modules that are limited in their ability to allow for the safe handling of potentially biohazardous blood samples. Systems that provide for injection of sample from a syringe use more than the required volume for sample testing and have the potential for causing splash-back of the sample if the introduction port is blocked. The probes of aspiration-based systems require manual dexterity by the operator and present the possibility of operator injury with a contaminated probe tip or the possibility of system damage as the probe extends and the operator moves the collection device into place. Some systems have the potential for both types of biohazards. This report describes the implications for system design of the sample collection devices commonly in use, and it offers a design solution that combines the ergonomics of an injection system and the operational advantages of an aspiration system, in combination, addressing the biosafety aspects in a unique fashion.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B R Degen, R F Moran, P N Karkantis. 1996. Biosafety implications in sample introduction: module design characteristics for discrete-sample systems used in critical whole blood analyte testing environments.. https://doi.org/10.3109/00365519609088629

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Laparoscopic surgery impairs tissue oxygen tension more than open surgery.

BACKGROUND: Wound infection remains a common and serious complication after colonic surgery. Although many colonic operations are performed laparoscopically, it remains unclear whether this has any impact on the incidence of wound infection. Subcutaneous tissue oxygenation is an excellent predictor of surgical wound infection. The impact of open and laparoscopic colonic surgery on tissue oxygenation was compared. METHODS: Fifty-two patients undergoing elective open and laparoscopic left-sided colonic resections were evaluated in a prospective observational study. Anaesthesia management was standardized and intraoperative arterial partial pressure of oxygen was kept at 150 mmHg in both groups. Oxygen tension was measured in the subcutaneous tissue of the right upper arm. RESULTS: At the start of surgery subcutaneous tissue oxygen tension (PsqO(2)) was similar in both groups (mean(s.d.) 65.8(17.2) and 63.7(23.6) mmHg for open and laparoscopic operations respectively; P = 0.714). Tissue oxygen remained stable in the open group, but dropped significantly in the laparoscopic group during the course of surgery (PsqO(2) after operation 53.4(12.9) and 45.5(11.6) mmHg, respectively; P = 0.012). CONCLUSION: Laparoscopic colonic surgery significantly decreases PsqO(2), an effect that occurs early in the course of surgery. As tissue oxygen tension is a predictor of wound infection, these results may explain why the risk of wound infection after laparoscopic surgery remains higher than expected.

Blood Gas Analysis↗

Open and closed endotracheal suction systems in mechanically ventilated intensive care patients: a meta-analysis.

BACKGROUND: Closed suction systems (CSS) are increasingly replacing open suction systems (OSS) to perform endotracheal toilet in mechanically ventilated intensive care unit patients. Yet effectiveness regarding patient safety and costs of these systems has not been carefully analyzed. OBJECTIVE: To review effectiveness of CSS and OSS, with respect to patient outcome, bacterial contamination, and costs in adult intensive care unit patients. DATA SOURCE: Search of MEDLINE, CINAHL, EMBASE, and Cochrane databases and a manual review of article bibliographies. STUDY SELECTION: Randomized controlled trials comparing CSS and OSS in adult intensive care unit patients were retrieved. DATA EXTRACTION/SYNTHESIS: Assessment of abstracts and study quality was performed by two reviewers. Data were combined in meta-analyses by random effect models. Fifteen trials were identified. No significant differences were found in incidences of ventilator-associated pneumonia (eight studies, 1,272 patients) and mortality (four studies, 1,062 patients). No conclusions could be drawn with respect to arterial oxygen saturation (five studies, 109 patients), arterial oxygen tension (two studies, 19 patients), and secretion removal (two studies, 37 patients). Compared with OSS, endotracheal suctioning with CSS significantly reduced changes in heart rate (four studies, 85 patients; weighted mean difference, -6.33; 95% confidence interval, -10.80 to -1.87) and changes in mean arterial pressure (three studies, 59 patients; standardized mean difference, -0.43; 95% confidence interval, -0.87 to 0.00) but increased colonization (two studies, 126 patients; relative risk, 1.51; 95% confidence interval, 1.12-2.04). CSS seems to be more expensive than OSS. CONCLUSIONS: Based on the results of this meta-analysis, there is no evidence to prefer CSS more than OSS.

Blood Gas Analysis↗