Sweat testing in opioid users with a sweat patch.

Abstract

For many years, toxicologists have detected the presence of drugs of abuse in biological materials using blood or urine. In recent years, remarkable advances in sensitive analytical techniques have enabled the analysis of drugs in unconventional samples such as sweat. In a study conducted in a detoxification center, sweat patches were applied to 20 known heroin abusers. Subjects wore the patch with minimal discomfort for five days. During the same period, two urine specimens were also collected. Target drugs analyzed either by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-mass spectrometry (LC-MS) included opiates (heroin, 6-monoacetylmorphine, morphine, codeine), cocaine (cocaine, benzoylecgonine, ecgonine methyl ester), delta 9-tetrahydrocannabinol, benzodiazepines (nordiazepam, oxazepam), amphetamines (amphetamine, methamphetamine, methylenedioxyamphetamine [MDA], methylenedioxymethamphetamine [MDMA], methylenedioxyethylamphetamine [MDEA]), and buprenorphine. Patches were positive for opiates in 12 cases. Heroin (37-175 ng/patch) and/or 6-acetylmorphine (60-2386 ng/patch) were identified in eight cases, and codeine exposure (67-4018 ng/patch) was determined in four cases. When detected, heroin was always present in lower concentrations than 6-acetylmorphine, which was the major analyte found in sweat. Cocaine (324 ng/patch) and metabolites were found in only one case. delta 9-Tetrahydrocannabinol (4-38 ng/patch) was identified in nine cases. Benzodiazepine concentrations were very low, ranging from 2 to 44 and from 2 to 15 ng/patch for nordiazepam and oxazepam, respectively. MDEA (121 ng/patch) and its metabolite, MDA (22 ng/patch), were detected in one case. Buprenorphine, which was administered as therapy under close medical supervision, was detected in the range 1.3-153.2 ng/patch with no apparent relationship between the daily dose and amount excreted in sweat. All the urine tests were consistent with the sweat findings, but to identify the same drugs it was necessary to test two urine specimens along with only one sweat specimen. It was concluded that sweat testing appears to offer the advantage of being a relatively noninvasive means of obtaining a cumulative estimate of drug exposure over the period of a week. This new technology may find useful applications in the treatment and monitoring of substance abusers, as the patch provides a long-term continuous monitor of drug exposure or noncompliance.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Kintz, A Tracqui, P Mangin, Y Edel. 1996. Sweat testing in opioid users with a sweat patch.. https://doi.org/10.1093/jat%2F20.6.393

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparisons of hallucinogenic phenylisopropylamine binding affinities at cloned human 5-HT2A, -HT(2B) and 5-HT2C receptors.

Since the classical hallucinogens were initially reported to produce their behavioral effects via a 5-HT2 agonist mechanism (i.e., the 5-HT2 hypothesis of hallucinogen action), 5-HT2 receptors have been demonstrated to represent a family of receptors that consists of three distinct subpopulations: 5-HT2A, 5-HT2B, and 5-HT2C receptors. Today, there is greater support for 5-HT2A than for 5-HT2C receptor involvement in the behavioral effects evoked by these agents. However, with the recent discovery of 5-HT2B receptors, a new question arises: do classical hallucinogens bind at 5-HT2B receptors? In the present study we examined and compared the binding of 17 phenylisopropylamines at human 5-HT2A, 5-HT2B, and 5-HT2C receptors. Although there was a notable positive correlation (r>0.9) between the affinities of the agents at all three populations of 5-HT2 receptors, structural modification resulted only in small differences in 5-HT2B receptor affinity such that the range of affinities was only about 50-fold. As with 5-HT2A and 5-HT2C receptor affinity, there is a significant correlation (r>0.9, n=8) between 5-HT2B receptor affinity and human hallucinogenic potency. Nevertheless, given that 5-HT2A and 5-HT2A/2C antagonists - antagonists with low affinity for 5-HT2B receptors - have been previously shown to block the stimulus effects of phenylisopropylamine hallucinogens, it is likely that 5-HT2A receptors play a more prominent role than 5-HT2B and 5-HT2C receptors in mediating such effects despite the affinity of these agents for all three 5-HT2 receptor subpopulations.

Amphetamines

Metabolic production of amphetamine following administration of clobenzorex.

Many of the anorectic drugs that are metabolized to amphetamine and/or methamphetamine pose significant concerns in the interpretation of amphetamine-positive drug testing results. One of these drugs--clobenzorex--has been shown to produce amphetamine. Thirty milligrams of clobenzorex hydrochloride, in the form of a single Asenlix capsule (Roussel, Mexico), were administered orally to five human volunteers with no history of amphetamine, methamphetamine or clobenzorex use. Following administration, urine samples (total void volume) were collected ad lib for seven days and pH, specific gravity and creatinine values were determined. To determine the excretion profile of amphetamine and parent drug, samples were extracted, derivatized, and analyzed by gas chromatography/mass spectrometry (GC/MS) using a standard amphetamine procedure with additional monitoring of ions at m/z 91, 118, 125 and 364 for the detection of clobenzorex. Peak concentrations of amphetamine were detected at 4 to 19 h postdose and ranged from approximately 715 to 2474 ng/mL amphetamine. Amphetamine could be detected (> 5 ng/mL) in the urine in one subject for up to 116 h postdose. GC/MS was also used to determine the enantiomeric composition of the metabolite, amphetamine. This analysis revealed the metabolically derived amphetamine was only the d-enantiomer. This differs from previous literature which indicates clobenzorex is the racemic N-orthochlorobenzyl derivative of amphetamine.