PubMed HealthSearch

PubMed · 8925864

Performing the 75SeHCAT test using a collimated gamma camera.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Martin-Comin, P A de Lima Ramos. 1996. Performing the 75SeHCAT test using a collimated gamma camera.. https://doi.org/10.1007/bf00834540

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Superiority of triple-detector single-photon emission tomography over single- and dual-detector systems in the minimization of motion artefacts.

A patient motion-related artefact is one of the most important artefacts in single-photon emission tomography (SPET) imaging. This study evaluated the effect of the number and configuration of SPET detectors on motion artefacts. The following acquisition conditions were simulated based on original 360 degrees projection images: (1) single-detector 180 degrees rotation (S180), (2) a dual-detector rectangular (L-shaped) 180 degrees acquisition (D180L), (3) dual-detector cameras mounted opposite each other with 360 degrees acquisition (D360) and (4) triple-detector 360 degrees acquisition (T360). The motion artefacts were introduced using a syringe and a myocardial phantom. Clinical cases with technetium-99m methoxyisobutylisonitrile and thallium-201 studies were analysed to confirm the validity of this phantom simulation. The effect of continuous alternate rotation acquisition and summing the projections on the reduction of motion artefacts was investigated in each model. The effect of motion depended on the number and the configuration of the SPET detectors. A 1-pixel (6.4 mm) motion in the S180, D180L and D360 models generated only slight artefacts, and a 2-pixel motion led to an apparent decrease in activity or created hot areas in the myocardium. On the other hand, a T360 rotation created few artefacts even with a 2-pixel motion of the last quarter of the projections. Despite the difference in attenuation with 201Tl and 99mTc, similar artefact patterns were observed with both radionuclides in selected patient model studies. Continuous alternate rotation could reduce artefacts caused by less than a 2-pixel motion. In conclusion, calculating the average of the sum of the projections of triple-detector 360 degrees rotations with alternate rotation is the best method to minimize motion artefacts. This "averaging" effect of motion artefacts is a key to this simulation.

Gamma Cameras

Scintigraphic evaluation of functional thyroidal autonomy.

The scintigraphic evaluation of thyroidal autonomy is performed both as a quantitative and qualitative thyroid scintigraphy with 99m-Tc-pertechnetate (99m-TcO4-), using a gamma camera fitted with an on-line computer system. A strong and linear correlation between the global 99m-Tc-pertechnetate thyroid uptake (TCTU) and I-123 clearance has been recognised. Therefore TCTU-values can be used as an reliable equivalent of the iodine clearance in the evaluation of actual thyroid function. The clinical value of the TCTU in the diagnosis of thyroidal autonomy is limited because it represents iodine clearance of both normal and autonomous tissue. As a consequence scintigraphic diagnosis and quantification of autonomy can only be established if the global 99m-Tc-pertechnetate thyroid uptake under suppression (TCTUs) is determined. This method is valuable in risk stratification of spontaneous or iodine induced hyperthyroidism, in the estimation of the target volume prior to radioiodine therapy and in the evaluation of therapeutic success after definitive therapy.

Gamma Cameras