PubMed HealthSearch

PubMed · 8947809

Sarin.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Morgan-Jones, T Hodgetts. 1996. Sarin.. https://doi.org/10.1136/emj.13.6.431-c

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Analysis of VX on soil particles using ion trap secondary ion mass spectrometry.

The direct detection of the nerve agent VX (methylphosphonothioic acid, S-[2-[bis(1-methylethyl)amino]ethyl] O-ethyl ester) on milligram quantities of soil particles has been achieved using ion trap secondary ion mass spectrometry (IT-SIMS). VX is highly adsorptive toward a wide variety of surfaces; this attribute makes detection using gas-phase approaches difficult but renders the compound very amenable to surface detection. An ion trap mass spectrometer, modified to perform SIMS, was employed in the present study. A primary ion beam (ReO4-) was fired on axis through the ion trap, where it impacted the soil particle samples. [VX + H]+, [VX + H]+ fragment ions, and ions from the chemical background were sputtered into the gas-phase environment of the ion trap, where they were either scanned out or isolated and fragmented (MS2). At a surface concentration of 0.4 monolayer, intact [VX + H]+, and its fragment ions, were readily observable above background. However, at lower concentrations, the secondary ion signal from VX became obscured by ions derived from the chemical background on the surface of the soil particles. MS2 analysis using the ion trap was employed to improve detection of lower concentrations of VX: detection of the 34S isotopic ion of [VX + H]+, present at a surface concentration of approximately 0.002 monolayer, was accomplished. The study afforded the opportunity to investigate the fragmentation chemistry of VX. Semiempirical calculations suggest strongly that the molecule is protonated at the N atom. Deuterium labeling showed that formation of the base peak ion (C2H4)N(i-C3H7)2+ involves transfer of the amino proton to the phosphonothioate moiety prior to, or concurrent with, C-S bond cleavage. To manage the risk associated with working with the compound, the vacuum unit of the IT-SIMS was located in a hood, connected by cables to the externally located electronics and computer.

Chemical Warfare Agents

Packed capillary liquid chromatography-electrospray mass spectrometry analysis of organophosphorus chemical warfare agents.

Packed capillary column liquid chromatography (LC)-electrospray mass spectrometry (ESI-MS) was used for the first time to detect and identify four common organophosphorus chemical warfare agents in aqueous samples. Aqueous samples containing the organophosphorus chemical warfare agents in the 0.01 to 0.1 mg/ml range were analyzed directly by packed capillary LC-ESI-MS with the chemical warfare agents and several minor related impurities being well resolved under acetonitrile-water gradient elution conditions. The ESI-MS data for isopropyl methylphosphonofluoridate (sarin or GB), O-ethyl N,N-dimethylphosphoramidocyanidate (tabun or GA), cyclohexyl methylphosphonofluoridate (GF) and pinacolyl methylphosphonofluoridate (soman or GD) were acquired with a sampling cone voltage setting that promoted collisionally activated dissociation, and resulted in the acquisition of informative mass spectra containing both molecular and product ion information. The developed method appears to be an attractive alternative to GC-MS for the analysis of aqueous samples containing organophosphorus chemical warfare agents and their hydrolysis products, since they may be analyzed directly without the need for additional sample handling.

Chemical Warfare Agents

Analysis of O-ethyl S-[2-(diisopropylamino)ethyl] methylphosphonothiolate (VX) and its degradation products by packed capillary liquid chromatography-electrospray mass spectrometry.

Packed capillary column liquid chromatography (LC)-electrospray mass spectrometry (ESI-MS) was used for the first time to detect and identify O-ethyl, S-[2-(diisopropylamino)ethyl] methylphosphonothiolate (VX) and its degradation products, including compounds containing a P-CH3 bond, bis(diisopropylamino)thioalkanes and ureas commonly employed as VX stabilizers. The reported ESI-MS data were generally acquired with a higher sampling cone voltage, a setting that promoted collisionally activated dissociation, and resulted in the acquisition in informative mass spectra containing both molecular and product ion information. The developed method appears to be an attractive alternative to GC-MS for the analysis of aqueous sample containing the degradation products of VX, since they may be analysed directly with little risk of thermal decomposition and without the need for additional sample handling or derivatization. Application of this method to a degraded VX sample resulted in the detection of a number of novel polar and higher-molecular-mass degradation products, not previously associated with VX during GC-MS analysis.

Chemical Warfare Agents