PubMed HealthSearch

PubMed · 8973956

A quantitative method for comparing and evaluating manual prosthetic socket modifications.

Abstract

Manually designed prosthetic sockets are difficult to evaluate since the hand-sculpting modification process does not retain the initial shape for comparison. A quantitative method for defining and comparing manual socket modifications was developed and integrated into the CADVIEW software package. The numerical comparison procedure consisted of a) digitizing premodification and post-modification models of a prosthetic socket, b) aligning these two shapes to a common axis (calculate cross section centroids, determine line of best fit through the centroids, rotate and move the line of best fit to a common axis), and c) displaying the differences in shape both numerically and using a color-coded three dimensional image. Alignment technique testing showed a between-radial-point average error of 2.5 mm using automatic alignment and 1.4 mm after further manual alignment adjustment. The between socket difference values were used to outline individual modifications and save these outlines to disk. Modification outlines from a series of patients were averaged to determine a prosthetist's general modification style. Averaged results from two prosthetists qualitatively supported the effectiveness of this procedure. This alignment and comparison system should help transfer hand-sculpting skills to prosthetic CAD/CAM systems, clinical research, and education for new clinicians.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E D Lemaire, F Johnson. 1996. A quantitative method for comparing and evaluating manual prosthetic socket modifications.. https://doi.org/10.1109/86.547931

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Stimulation of axon growth from the spinal cord by a regenerating limb blastema in newts.

The effects of limb blastemas of Pleurodeles waltl on axon growth from fragments of spinal cord were studied in vitro. Cultured in a defined medium, spinal cord fragments regenerated sparse, short axons. The culture of spinal fragments in the presence of blastemas greatly enhanced the length, number and survival of axons. Testing separately each of the two components of the blastema showed that only the mesenchyme exerts a neurotropic effect on the spinal fragments. Other tissues such as muscle or skin had a limited neurotrophic effect. Additionally, the neurotrophic activity of blastemas seems to be dependent of its proliferation status. Compared with blastemas of regenerating limbs from young animals, irradiated blastemas (devoid of mitotic activity) and blastemas of regenerating limbs from old animals or differentiated blastemas (both characterized by a low mitotic activity), exhibited a weaker neurotrophic influence. The blastema neurotrophic factor is not an attachment molecule but a soluble one and cannot be nerve growth factor (NGF) or fibroblast growth factor (FGF). It has a relatively low molecular weight (less than 15 kDa) and its protein nature was ascertained by its sensitivity to heating and proteases. As the production of this mesenchyme-derived neurotrophic factor depends upon mesenchymal cell proliferation of the blastema, we suggest that there is loop of positive regulation between spinal nerves and blastema. Blastema tissues may stimulate nerve regeneration allowing the stimulation of proliferation of blastema cells by regenerating nerve fibers. Alternatively, blastema cells may produce a neurotrophic factor whose secretion might be dependent on cell proliferation.

Amputation Stumps

Phantom limb pain: a review of the literature on attributes and potential mechanisms.

This study presents a review of the literature on the attributes and potential mechanisms involved in phantom limb pain, encompassing studies describing pain in the residual limb, phantom sensation and phantom limb pain, and the difficulties that may arise when making these distinctions. A variety of theories have been proposed to explain causal mechanisms for phantom limb pain. Conceptually, research into phantom limb pain is informed by the particular theory of chronic pain that is dominant at the time the research is undertaken. For example, early physiological theories on the etiology of phantom limb pain were grounded in specificity or pattern theories of pain. Later physiological research was based on the framework provided by Gate Control Theory and focused on identifying peripheral, spinal, and central neural mechanisms. Psychological explanations were grounded in psychoanalytic or personality theories of chronic pain which propose that phantom limb pain results from pre-amputation psychological disturbance. Despite numerous studies examining phantom limb pain, much of this research has both conceptual and methodological shortcomings. As such, the application of these research findings to clinical practice has limited utility.

Amputation Stumps