PubMed Health⌕ Search

PubMed · 9025128

Active compression-decompression resuscitation: a prospective, randomized study in a two-tiered EMS system with physicians in the field.

Abstract

Improved cardiopulmonary circulation with active compression-decompression cardiopulmonary resuscitation (ACD-CPR) has been demonstrated in studies using different animal models and a small number of humans in cardiac arrest (CA). However, prehospital studies have shown both positive and no extra benefit of ACD-CPR on return of spontaneous circulation (ROSC), hospital admission and discharge rates. The aim of our prospective study was to compare standard manual CPR (S-CPR) with ACD-CPR as the initial technique of resuscitating patients with out-of-hospital CA, with respect to survival rates and neurological outcome. Patients with out-of-hospital CA treated by emergency medical services (EMS) personnel were randomly assigned to one of two groups (ACD-CPR versus S-CPR). Time intervals to key measures were documented by means of on-line tape-recording. Neurological outcome was assessed using standard scoring systems (cerebral and overall performance categories (CPC and OPC)). A total of 220 patients (S-CPR, n = 114: ACD-CPR, n = 106) were included in the study in a random order. The treatment groups were similar with respect to age, sex, time interval from collapse to CPR, defibrillation and first adrenaline medication. There was no difference between the ACD group and the standard CPR group in terms of ROSC (50.9% vs. 59.6%), hospital admission (33% vs. 33.3%), hospital discharge (16% vs. 14%), or CPC and OPC (1.82 vs. 2.13 and 2.06 vs. 2.25, respectively). Concerning complications of CPR, there was no difference between the groups. In our two-tiered EMS system with physician-staffed ambulances, ACD-CPR neither improved nor impaired survival rates and neurological prognosis in patients with out-of-hospital cardiac arrest. The new CPR technique did not increase the complications associated with the resuscitation effort.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Mauer, T Schneider, W Dick, A Withelm, D Elich, M Mauer. 1996. Active compression-decompression resuscitation: a prospective, randomized study in a two-tiered EMS system with physicians in the field.. https://doi.org/10.1016/s0300-9572(96)01006-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparison of ventilation and chest compression performance by bystanders using the Impact Model 730 ventilator and a conventional bag valve with mask in a model of adult cardiopulmonary arrest.

"Bystanders" or lay persons are typically the first caregivers to attend to a victim of out-of-hospital cardiopulmonary arrest. Astronaut crew medical officers (CMO) play a similar role to bystanders aboard the International Space Station (ISS). Studies have demonstrated the importance of bystander cardiopulmonary resuscitation (BCPR) for patient survival before the arrival of emergency medical care. Recent apprehension from bystanders about the threat of contracting communicable diseases during BCPR, however, has led to the consideration of other ventilation systems such as the bag-valve mask (BVM) and automatic transport ventilators (ATV). BVM use is called for during CPR aboard the ISS. This study evaluated the ventilation and compression performance of 40 basic CPR-trained bystanders using either a BVM (adult-sized self-inflating bag with face mask) or an ATV (Model 730 ventilator (M730), Impact Instrumentation, Inc., West Caldwell, NJ). Each two-bystander team gave BCPR to a simulated cardiopulmonary arrest victim using the 2-breath/15-compression cycle for 4 min and then switched roles for another 4-min interval. Compared to BVM use, the M730 led to significantly (p<0.05) lower number of breaths, smaller tidal volumes, airway flows, airway pressures, volume of gas entering the stomach per breath and chest compressions for the 4-min period. The M730 also enabled a bystander to meet the recommendation of 4-breath and compression cycles per minute as per Guidelines 2000. Lastly, ease-of-use scores were significantly higher for the M730 compared to the BVM. Overall, the data suggest that the M730 improves the quality of performance for a bystander performing BCPR.

Cardiopulmonary Resuscitation↗