PubMed Health⌕ Search

PubMed · 9059877

Bone densitometry: patients receiving prolonged steroid therapy.

Abstract

Bone mass loss and osteoporosis are associated with various conditions, such as asymptomatic primary hyperparathyroidism, and treatments, such as prolonged steroid therapy. Bone densitometry is used to measure bone mass density to determine the degree of osteoporosis and to estimate fracture risk. Bone densitometers measure the radiation absorption by the skeleton to determine bone mass of the peripheral, axial, and total skeleton. Common techniques include single-photon absorptiometry (SPA) of the forearm and heel, dual-photon (DPA) and dual-energy x-ray absorptiometry (DXA) of the spine and hip, quantitative computed tomography (QCT) of the spine or forearm, and radiographic absorptiometry (RA) of the hand. Part I of this report addresses important technical considerations of bone densitometers, including radiation dose, site selection, and accuracy and precision, as well as cost and charges. Part II evaluates the clinical utility of bone densitometry in the management of patients receiving prolonged steroid therapy. Steroids have broad effects on both immune and inflammatory processes and have been used to treat a wide variety of immunologically mediated diseases. Osteoporosis and vertebral compression fractures have been considered major complications of prolonged steroid therapy. Bone loss is also a direct result of many of the diseases treated with steroids. Issues addressed are the type and extent of bone loss associated with steroid therapy, risk for fracture, whether steroid dose reduction or alternative therapy is an option, and whether osteoporosis associated with prolonged steroid use can be prevented or treated. The other assessments in this series address the clinical utility of bone densitometry for patients with: asymptomatic primary hyperparathyroidism, end-stage renal disease, vertebral abnormalities, and estrogen-deficient women.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Erlichman, T V Holohan. 1996. Bone densitometry: patients receiving prolonged steroid therapy.. https://pubmed.ncbi.nlm.nih.gov/9059877/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗