PURPOSE: CT of total joint prostheses is limited by metal artifact produced mainly by missing projection data. Iterative deblurring reconstruction is less sensitive to missing projection data than filtered backprojection. A software CT simulator was used to compare total hip prosthesis images reconstructed using standard filtered backprojection, filtered backprojection after linear interpolation of missing data, and iterative deblurring. METHOD: Unilateral and bilateral total hip replacements with metal-backed or all-polyethylene acetabular prostheses were simulated using bone, metal, and polyethylene annuli and circles of metal and water (soft tissue). Material attenuation properties were taken from the literature. The simulation assumed that no X-rays penetrated the metal. Simulated projection data were reconstructed using filtered backprojection, filtered backprojection after linear interpolation of missing data, and iterative deblurring. Visual observations and objective region-of-interest analyses were made. RESULTS: Even with no X-rays penetrating the metal, iterative deblurring produced almost no visible artifact within the bone or soft tissues. Bone edge detection and sizing were more easily and accurately done from the iterative deblurring images. All reconstruction techniques underestimated bone and water CT attenuation values. Metal artifact was worse for the bilateral or metal-backed prostheses. CONCLUSION: Iterative deblurring generated nearly metal-artifact-free images in this simulation. Filtered backprojection, even after linear interpolation, produced typical clinical metal-artifact images.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D D Robertson, J Yuan, G Wang, M W Vannier. Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction.. https://doi.org/10.1097/00004728-199703000-00024

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗