Discrepancies in normative data between Lunar and Hologic DXA systems.

Abstract

Many studies have shown the high correlation between Lunar and Hologic DXA bone mineral density (BMD) measurements despite differences in absolute calibration. However, in clinical practice, raw BMD values (in g/cm2) are not normally used for assessing skeletal status and fracture risk. Instead, the BMD values are expressed in terms of the number of standard deviations above or below the young normal value (commonly referred to as the T-score). If the normative populations of the various systems are consistent, the standard deviation scores should also be consistent. For this reason, the World Health Organization (WHO) recently established diagnostic criteria for osteoporosis based on T-scores and not BMD. However, few studies have compared the instruments in terms of their standard deviation scores. In this study, we used linear regression to compare T-scores in 83 women at L1-4 and 120 women at the femoral neck obtained on a Lunar DPX and a Hologic QDR-1000/W system. patient BMD and T-score measurements were highly correlated between the two systems (r > 0.95). No clinically significant difference in L1-4 T-scores was seen (less than 0.1 SD). However, linear regression analysis confirmed a systematic difference of 0.9 SD between the femoral neck T-scores. This discrepancy is caused by: (1) differences in the normal populations, and (2) differences in statistical models used to determine the young normal mean and standard deviation. In an attempt to correct the discrepancy, the female young normal mean and standard deviation were recalculated for the femoral neck using published epidemiological data from NHANES and existing DXA cross-calibration equations. The Hologic young normal value (mean +/- SD) was redefined as 0.85 +/- 0.11 g/cm2, while the Lunar value was redefined as 1.00 +/- 0.11 g/cm2. When the femoral neck T-scores for the study population were recalculated on the basis of these new values, the results were equivalent between manufactures, effectively eliminating the discrepancy. However, the revised values should be confirmed by additional measurements in young normal adults.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K G Faulkner, L A Roberts, M R McClung. 1996. Discrepancies in normative data between Lunar and Hologic DXA systems.. https://doi.org/10.1007/bf01629574

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗