Processor quality control in laser imaging systems.

Abstract

Sensitometric techniques for performing processor quality control in laser imaging systems are analyzed in this study. The sensitivity of conventional x-ray films using simulated screen-light sensitometry is compared with helium-neon (HeNe) laser film exposed with a simulated red-light sensitometer, a standalone (reference) laser sensitometer, an experimental (unstable) laser sensitometer, and laser printers. Infrared (IR) laser film exposed with an IR laser diode and a simulated IR sensitometer are also evaluated. It is demonstrated that laser-generated step tablets provide an easy and reliable method of performing laser film processor quality control.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T M Bogucki, W R Murphy, C W Baker, S S Piazza, A G Haus. 1997. Processor quality control in laser imaging systems.. https://doi.org/10.1118/1.597940

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Ultrastructural changes in chondriome of human lymphocytes after irradiation with He-Ne laser: appearance of giant mitochondria.

The structure of mitochondria was studied after the irradiation of human lymphocytes with an He-Ne laser (wavelength, 632.8 nm; dose, 56 J m-2). Ultrathin sections of the lymphocytes were studied by electron microscopy 1 h after the irradiation. The irradiation resulted in a 20% increase (p = 0.95) in the number of mitochondrial profiles on the cell section without an increase in their total area. Three-dimensional reconstruction of mitochondria from ultrathin sections trough the whole lymphocyte showed that the number of mitochondria was reduced to 9-12 in the irradiated cells compared with 40-45 in the control cells. In the irradiated lymphocytes, 2-4 giant branching mitochondria were also observed among small discrete mitochondria.

Helium

Theoretical validation of the respiratory benefits of helium-oxygen mixtures.

A theoretical analysis of convective gas transport validates the clinically demonstrated advantage of using helium-oxygen mixtures in treating patients with respiratory problems. Previous studies have attributed that advantage to the ability of helium-oxygen to stay laminar at higher velocities than nitrogen-oxygen. The present work shows that helium-oxygen does not need to be laminar to provide higher flow rates and that its benefits persist under turbulent conditions. The analysis is applied to steady flow through the lungs and through a circular airway obstruction. A simplified model of the lungs gives pressure-flow relations that show a significant increase in oxygen flow rate when nitrogen is substituted by helium. A similar improvement is found for flow through an obstruction. For a given pressure difference across the lungs or across an obstruction, the turbulent flow rate of oxygen increases by approximately 50% when nitrogen is replaced by helium in a mixture containing 20% oxygen.

Helium