Field programmable gate array in a fast 256-channel data acquisition system.

Abstract

We describe an FPGA (Field Programmable Gate Array) controlled fast data acquisition system with 256 channels suitable for high resolution electrocardiographic (ECG), electrogastrographic (EGG) and late potential (LP) recordings. The A/D converter provides 800ns conversion time with 12 bits. The S11W, a 16 bit, parallel, I/O interface, is used to connect the data acquisition device to a portable SPARC-compatible computer. With only one A/D converter, we have achieved 2 kHz sampling rate for each channel and more than 1MB/s overall by using an overlapping delay technique. Channel parameters can be selected independently from one of eight gains ranging from 50 to 10,000, and one of three filters ("ECG" 0.05-120Hz, "EGG" 0.001-1Hz and "LP" 60-1kHz). There are eight programmable sampling frequencies from 2Hz to 2kHz. The system is fully battery operated and protected from the defibrillation high voltages to meet the safety requirements. The acquisition system can be widely used in medical research and clinical applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Y Li, W K Pluta, D Kilpatrick. 1997. Field programmable gate array in a fast 256-channel data acquisition system.. https://pubmed.ncbi.nlm.nih.gov/9141314/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Analog neural nets with gaussian or other common noise distribution cannot recognize arbitrary regular languages.

We consider recurrent analog neural nets where the output of each gate is subject to gaussian noise or any other common noise distribution that is nonzero on a sufficiently large part of the state-space. We show that many regular languages cannot be recognized by networks of this type, and we give a precise characterization of languages that can be recognized. This result implies severe constraints on possibilities for constructing recurrent analog neural nets that are robust against realistic types of analog noise. On the other hand, we present a method for constructing feedforward analog neural nets that are robust with regard to analog noise of this type.

Analog-Digital Conversion

Digital images.

This tutorial introduces basic digital image processing concepts. An increasing fraction of fluoroscopic images are handled and processed using digital tools. The quality of an image in digital format depends on both the technical details of the digitization process and on the quality of the starting scene. Digital tools yield images that are difficult or impossible to achieve using analog techniques. Proper processing improves the observer's perception of clinical information.

Analog-Digital Conversion

Electrophysical factors influencing endoscopic sphincterotomy.

BACKGROUND: Analog computer techniques were used to measure electrosurgical power during sphincterotomy in experimental models and patients. METHODS: Total energy and transient changes in power were measured during sphincterotomy of bile ducts in the livers of pigs, ampullae of humans post mortem, and during clinical sphincterotomy. The effect of waveform on hemostasis was studied in experiments on canine mesenteric arteries. RESULTS: Electrosurgical waveforms (CUT, COAG, BLEND) were measured. Halving wire contact length halved energy needed to initiate cutting. The CUT waveform rarely initiated cutting at lower power settings than the BLEND waveform. With CUT, BLEND, and COAG waveforms, approximately the same energy initiated cutting. Efficiency of cutting increased linearly with power. The COAG waveform required higher power settings than BLEND or CUT to initiate cutting (p < 0.05). Force and wire diameter influenced cutting. BLEND was more effectively hemostatic than CUT (p < 0.05). COAG was significantly more hemostatic than BLEND and CUT. Cutting efficiency during clinical sphincterotomy was poor. CONCLUSIONS: This work has practical implications. Shortening wire contact length was effective in starting a cut at suboptimal settings, whereas changing from BLEND to CUT made little difference. Increasing power setting may help if cutting does not start. BLEND stops bleeding better than CUT. COAG stops bleeding better than BLEND but cuts poorly. Cutting during clinical sphincterotomy is inefficient and can be improved.

Analog-Digital Conversion