Technical note. Modulation transfer function analysis of a newly revised rotational panoramic machine.

Abstract

OBJECTIVES: To determine the modulation transfer function (MTF) and noise equivalent passband (NE) values for a newly revised rotational panoramic X-ray machine, the PC-1000 (Panoramic Corp., Fort Wayne, Indiana, USA). METHODS: Images of a 10 microns test slit were taken at various locations along the X-ray beam projection path using a Lanex Regular/T-Mat G image receptor. Line spread functions were obtained at specific beam paths by scanning slit images with a microdensitometer. RESULTS: MTF values were highest around the central plane of the image layer, with a maximum near the centre of 0.25 at 4 cycles/mm. The NE values near the central plane of image layer were 1.4 cycles/mm. MTF and NE values in the anterior region were low, 0.2 and 1.2, respectively. The width of the image layer was narrower in the anterior and wider in the posterior segments. Rapid decreases in MTF and NE values were found on the X-ray tube side compared with the receptor side of the central plane. Using a spatial frequency of 0.25 MTF the shape of the image layer was coincident with that determined visually. CONCLUSION: On the basis of the MTF and NE values the image resolution produced by this machine is considered acceptable for panoramic dental radiography.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y Hayakawa, F E Eraso, W C Scarfe, A G Farman, K Nishikawa, K Kuroyanagi, M Smith. 1996. Technical note. Modulation transfer function analysis of a newly revised rotational panoramic machine.. https://doi.org/10.1259/dmfr.25.5.9161187

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Inverse planning for x-ray rotation therapy: a general solution of the inverse problem.

Rotation therapy with photons is currently under investigation for the delivery of intensity modulated radiotherapy (IMRT). An analytical approach for inverse treatment planning of this radiotherapy technique is described. The inverse problem for the delivery of arbitrary 2D dose profiles is first formulated and then solved analytically. In contrast to previously applied strategies for solving the inverse problem, it is shown that the most general solution for the fluence profiles consists of two independent solutions of different parity. A first analytical expression for both fluence profiles is derived. The mathematical derivation includes two different strategies, an elementary expansion of fluence and dose into polynomials and a more practical approach in terms of Fourier transforms. The obtained results are discussed in the context of previous work on this problem.

Mathematics

Geometry of circular vectors and pattern recognition of shape of a boundary.

This paper deals with pattern recognition of the shape of the boundary of closed figures on the basis of a circular sequence of measurements taken on the boundary at equal intervals of a suitably chosen argument with an arbitrary starting point. A distance measure between two boundaries is defined in such a way that it has zero value when the associated sequences of measurements coincide by shifting the starting point of one of the sequences. Such a distance measure, which is invariant to the starting point of the sequence of measurements, is used in identification or discrimination by the shape of the boundary of a closed figure. The mean shape of a given set of closed figures is defined, and tests of significance of differences in mean shape between populations are proposed.

Mathematics