PubMed Health⌕ Search

PubMed · 9165959

Is Hartmann's the solution?

Abstract

As Hartmann's solution is commonly used by anaesthetists, we surveyed a group of Part III FRCA candidates to establish their knowledge of its constituents and the purpose and metabolism of the lactate in solution. Of the 82 candidates surveyed only three (4%) accurately recorded the electrolytes and their concentrations in Hartmann's solution. Lactate was stated to be a source of bicarbonate by 52 (63%) and a source of glucose by 17 (21%). The descriptions of lactate metabolism were largely imprecise, none was complete and 24 (29%) of candidates offered no explanation. The constituents of Hartmann's solution and their concentrations are designed to match those of plasma, reducing ion and fluid shifts postinfusion. The lactate in Hartmann's solution is metabolised by both oxidation and gluconeogenesis, predominantly in the liver, and bicarbonate is generated by both processes over 1-2 h.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S A White, D R Goldhill. 1997. Is Hartmann's the solution?. https://doi.org/10.1111/j.1365-2044.1997.090-az0082.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Perception of training needs and opportunities in advanced airway skills: a survey of British and Irish trainees.

BACKGROUND AND OBJECTIVE: We surveyed delegates at the Group of Anaesthetists in Training (UK) meeting to investigate evidence of a training-gap (number of fibreoptic intubations believed to bestow competence vs. number actually performed). METHODS: Questionnaires were distributed to and collected from delegates in person. Questions covered six areas, including experience of fibreoptic intubation and cricothyrotomy, fibreoptic intubation as a specialist skill and ethical issues. RESULTS: We received 221 replies (76%). All trainees believed competence to be achievable with 10 intubations (interquartile range (IQR) 10-20); the median number performed was 2 (IQR 0-4). This was statistically significant for the groups' senior house officers, 1st and 2nd year registrars and 3rd and 4th year registrars; P < 0.0001. Many final year trainees (12/20, 60%) also failed to achieve their competency target. Few trainees had seen or performed any cricothyrotomies (medians 0, IQRs 0-1 and 0-0). Most (195/208, 94%) believed that fibreoptic intubation was a core skill and 199/212 (94%) believed that all should be competent by completion of training. Ten percent (n = 208) felt it unethical to perform an awake training intubation with full consent and 10% believed it acceptable without explanation. Most (82.7%) would fibreoptically intubate an asleep patient (requiring intubation) without consent. CONCLUSION: Trainees reported a gap between their perception of competence and achievement in awake fibreoptic intubation. Simple and complex simulations and structured training programmes may help. Anaesthetists must address the ethics of clinical training in advanced airway management.

Anesthesiology↗