Root-end cavity preparation using the MicroMega Sonic Retro-prep Tip. SEM analysis.

Abstract

The objective of this laboratory study was to compare root-end cavities prepared with sonic Retro-prep tips in a MM1500 Sonic Air handpiece with those created by burs in a conventional handpiece. A total of 80 single-rooted extracted human teeth with mature apices and straight canals were included in the study. Four groups of 20 extracted teeth were prepared as follows: I, a 3-4 mm root-end resection perpendicular to the long axis of the root, with a size 40 sonic Retro-prep tip creating an apical cavity 3 mm into root canal system; II, a 45 degrees bevel of the root-face removing a 3-4 mm root segment and root-end preparation as per group I; III, root-end resection as per group I, with an apical cavity prepared using a size 010 inverted cone bur 3 mm down the long axis of the root; IV, resection as per group II, followed by an apical cavity preparation with a size 010 inverted cone bur 3 mm into the root canal system. The apical root portion and root-end cavities were replicated and prepared for SEM analysis at x 20 and x 80 magnification. The degree of chipping associated with the margin of the root-end cavities, as evaluated with a standard grading system, and the incidence of root-face cracks were noted. Marginal chipping of root-end cavities prepared using sonic instrumentation was significantly worse than that produced by burs (P < 0.001). Perpendicular root-end resections showed significantly better scores than bevelled root-end resections (P < 0.005). The incidence of root-face cracking was low with no significant difference between the experimental groups.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Lloyd, A Jaunberzins, P M Dummer, S Bryant. 1996. Root-end cavity preparation using the MicroMega Sonic Retro-prep Tip. SEM analysis.. https://doi.org/10.1111/j.1365-2591.1996.tb01388.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Detection of a second mesiobuccal canal in the mesiobuccal roots of maxillary first molar teeth.

OBJECTIVE: The aim of the present study was to determine whether the MB2 canal in the mesiobuccal root (MBR) of maxillary first molars could be identified through a clinical access cavity preparation, with and without magnification. STUDY DESIGN: One hundred extracted maxillary first molar teeth were collected. After a clinical access cavity preparation with careful use of bur to locate any additional canal (dentine troughing), the MB2 canals were located in 2 stages. Stage I was located with unaided vision and stage II was located under moderate magnification with x3.5 magnifying dental loupes. All specimens were stained, rendered transparent, and then classified. The number of canals detected by stage was analyzed statistically by a chi-square test. Statistical significance was considered to be P < or = .05. RESULTS: Under magnification, the number of detected MB2 canals was increased from 55 (56.7%) to 61 (62.9%) teeth. Cleared teeth showed 77.32% of MB2 canals. The effectiveness of MB2 location was 73.3% and 82.7% in stage I and stage II, respectively. There was no statistically significant difference between the 2 methods of detecting the MB2 canal (P = .3). CONCLUSIONS: The use of magnification enhanced the ability to detect the MB2 canals, although the difference was not statistically significant. The MB2 canals could not be detected in 16.5% of the teeth, mainly because of pulpal calcification.

Dental Instruments↗

Risk of hepatitis B virus transmission via dental handpieces and evaluation of an anti-suction device for prevention of transmission.

We evaluated the risk of hepatitis B virus (HBV) transmission via dental handpieces and the effects of an anti-suction device in preventing HBV contamination. The results of our study show that under certain conditions, HBV transmission can occur when an anti-suction device is used during dental procedures. We conclude that such devices may decrease contamination, but do not eliminate it.

Dental Instruments↗

Accuracy of the apex locating function of TCM Endo V in simulated conditions: a comparison study.

OBJECTIVE: The aim of this study was to evaluate the accuracy of the apex-locating function of the TCM Endo V and to compare the results to these of the Root ZX. STUDY DESIGN: Forty-seven extracted maxillary incisor teeth with mature apices and patent single root canals were used for the study. After the root surfaces were cleaned and access cavities were prepared, the true working lengths (TL) were determined with a #10 stainless steel file. All samples were mounted in an alginate model especially developed to test the apex locators. Both electronic apex locators were used according to the manufacturer's recommendations and adjusted to 0.5-mm accuracy to the apical foramen. EL(1) was designates as the working length measured with Root ZX and EL(2) was designated as the working length measured with TCM Endo V. A paired t test was used to statistically analyze the significance of the mean differences at the 95% confidence interval of the differences (P = .001) among TL, EL(1), and EL(2). RESULTS: There were no statistically significant differences between TL and EL(1), TL and EL(2), and EL(1) and EL(2) (P = .001). Both Root ZX and TCM Endo V gave similar results. CONCLUSIONS: TCM Endo V proved to be as reliable as Root ZX but the use of the device to determine the working length was not easy as Root ZX. Further studies are needed to compare TCM Endo V in clinical conditions with similar electric motor and apex locator combined devices.

Dental Instruments↗