PubMed Health⌕ Search

PubMed · 9243157

Multiple restenoses following PTCA.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B Eber, O Luha, W Klein. 1997. Multiple restenoses following PTCA.. https://doi.org/10.1093/oxfordjournals.eurheartj.a015419

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Early and long-term results of stenting of diffuse coronary artery disease.

Diffuse coronary artery disease (CAD) is considered unfavorable for interventional procedures; however, the results of stenting of diffuse CAD have not been completely characterized. We performed stenting in 100 consecutive patients with diffuse CAD, defined as significant stenosis >20 mm (n = 59 patients), multiple significant stenoses in the same artery (n = 23 patients), or significant narrowing involving the whole length of the coronary artery (n = 18 patients). Angiographic success was achieved in 103 arteries (100%) and clinical success was obtained in all 100 patients. There were no deaths; no patient had stent closure, acute myocardial infarction, or required emergency coronary artery bypass surgery. All 100 patients had >6 months follow-up (mean 18 +/- 7 months, range 7 to 31); 77 (77%) remained asymptomatic, and 5 (5%) had acute myocardial infarction, of whom 2 died (2%). In-stent restenosis was observed in 12 patients (12%) and repeat angioplasty was performed in 10. Including those patients who underwent repeat angioplasty, 89 (89%) maintained clinical improvement and 95 (95%) were alive and free of bypass surgery during follow-up. Life-table analysis showed 86% freedom from death, myocardial infarction, and target lesion revascularization at 28 months. Thus, selected patients with diffuse CAD may be treated with satisfactory acute and long-term results by stent implantation.

Angioplasty, Balloon, Coronary↗

Longitudinal plaque redistribution during stent expansion.

The purpose of this study was to clarify the 3-dimensional behavior of plaque during coronary stent expansion. Serial intravascular ultrasound (IVUS) studies, preintervention, and poststenting were evaluated in 32 patients treated with a single-balloon expandable tubular stent. External elastic membrane (EEM), lumen, stent, and plaque + media cross-sectional area were measured at 1-mm intervals through the entire stent as well as proximal and distal reference segments 5 mm from the stent edge. Volumetric calculations were based on Simpson's rule. Overall, the plaque + media volume through the entire lesion did not change during stent expansion (218 +/- 51 vs 217 +/- 47 mm3, p = 0.69). However, EEM and lumen volume increased significantly (EEM volume, 391 +/- 84 vs 448 +/- 87 mm3 [p < 0.0001]; lumen volume, 173 +/- 52 vs 231 +/- 54 mm3 [p < 0.0001]). The change in lumen volume correlated strongly with the change in EEM volume (r = 0.85, p < 0.0001), but poorly with the change in plaque + media volume (r = 0.37, p = 0.03). Plaque + media volume decreased in the midstent zone (59 +/- 14 vs 53 +/- 11 mm3, p = 0.0005), and increased in the distal stent zone (40 +/- 11 vs 44 +/- 9 mm3, p = 0.003), but did not change in either the proximal stent zone or reference segments. The mechanism of stent expansion is a combination of vessel stretch and plaque redistribution, translating disease accumulation from the midstent zone to the distal stent zone.

Angioplasty, Balloon, Coronary↗