Quality framework for force plate testing.

Abstract

Following work done in C.E.C. project AIM 2002 CAMARC II, a framework of the relevant standards for testing equipment used in laboratories analysing human movement is presented. In particular, gait analysis laboratories may provide a service for a clinical team considering treatment such as surgical intervention or provision of orthoses. In this case the analysis and equipment used in the analysis must have assured quality so that the correct clinical interpretation of the results is possible. The operation of a gait analysis laboratory may be described in quality standards terminology as the operation of a 'special process'. The operation of a special process requires that particular attention be paid to procedures including confirmation of the equipment and regular testing to ensure correct operation of the equipment. In general this is difficult to achieve since equipment manufacturers still have to address this technical requirement. Although difficult, these procedures must be accomplished in the operation of a special process. Passages of the most pertinent standards are presented and a methodology of a periodic confirmation and regular spot checking of equipment suggested to ensure its correct operation. Although force plates are specifically addressed, the framework could be applied to other dynamometers and measurement equipment.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H E Fleming, M G Hall, M J Dolan, J P Paul. 1997. Quality framework for force plate testing.. https://doi.org/10.1243/0954411971534322

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Potentiometric sensor for methylene blue based on methylene blue-silicotungstate ion association and its pharmaceutical applications.

A methylene blue (MB) poly(vinyl chloride) membrane sensor based on MB-silicotungstate (SLT) ion association as electroactive material was described. The linear response covered the range 1 x 10(-3)-1 x 10(-6) mol x dm(-3) MB solution, with a slope 52.0+/-0.8 mV decade(-1) (pH range 3.0-10.0). The detection limit was 7.65 x 10(-7) mol x dm(-3). The electrode showed stability, good reproducibility and fast response. Interferences from common inorganic cations, some organic base were negligible. These characteristics of the electrode enabled it to be used successfully for the determination of MB in injection. There was a good agreement for the results of MB content in injection between potentiometric method and USP standard procedure.

Calibration

Determination of trace elements in a large series of spent peritoneal dialysis fluids by atomic absorption spectrometry.

An analytical procedure is reported for the determination of six elements in a large series of spent dialysis fluid samples. Determinations of aluminium, chromium, copper, manganese and iron were made by electrothermal atomic absorption spectrometry (ETAAS) with Zeeman background correction, while zinc was analysed by flame atomic absorption spectrometry (FAAS). Because of the complex matrix with high salt content and a high content of proteins, the measurement parameters were optimised for each particular element determined by ETAAS. The samples were collected in polyethylene eppendorf cups and stored in a freezer at -20 degrees C. When the elements were determined by ETAAS the standard addition method was applied in the calibration procedure. The sample (10 microl) was injected into a cuvette and careful drying and long ashing of samples at temperatures between 850 and 1000 degrees C performed. Triton X-100 was added before each determination to reduce the matrix effects of the proteins. Zinc was determined by FAAS in an air acetylene flame under the usual recommended procedure, calibrating with aqueous standards. The limits of detection (3sigma basis) were 1.0 microg x l(-1) for aluminium, 0.20 microg x l(-1) for chromium, 0.40 microg x l(-1) for copper, 0.20 microg x l(-1) for manganese, 0.50 microg x l(-1) for iron and 5.0 microg x l(-1) for zinc. The reproducibility of the measurements for aluminium, copper, iron and zinc was better than +/-3.0%. It was worse for manganese and chromium (+/-6.0 and +/-12.0%, respectively), since these two elements were present in very low concentrations in all the samples analysed.

Calibration

Cryptococcus neoformans resides in an acidic phagolysosome of human macrophages.

Recently, we demonstrated that human monocyte-derived macrophages (MDM) treated with chloroquine or ammonium chloride had markedly increased antifungal activity against the AIDS-related pathogen Cryptococcus neoformans. Both of these agents raise the lysosomal pH, which suggested that the increased antifungal activity was a function of alkalinizing the phagolysosome. Moreover, there was an inverse correlation between growth of C. neoformans in cell-free media and pH. These data suggested that C. neoformans was well adapted to survive within acidic compartments. To test this hypothesis, we performed studies to determine the pH of human MDM and neutrophil phagosomes containing C. neoformans. Fungi were labeled with the isothiocyanate derivatives of two pH-sensitive probes: fluorescein and 2',7'-difluorofluorescein (Oregon Green). These probes have pKas of 6.4 and 4.7, respectively, allowing sensitive pH detection over a broad range. The phagosomal pH averaged approximately 5 after ingestion of either live or heat-killed fungi and remained relatively constant over time, which suggested that C. neoformans does not actively regulate the pH of its phagosome. The addition of 10 and 100 microM chloroquine resulted in increases in the phagosomal pH from a baseline of 5.1 up to 6.5 and 7.3, respectively. Finally, by immunofluorescence, colocalization of C. neoformans and the MDM lysosomal membrane protein LAMP-1 was demonstrated, establishing that fusion of C. neoformans-laden phagosomes with lysosomal compartments takes place. Thus, unlike many other intracellular pathogens, C. neoformans does not avoid fusion with macrophage lysosomal compartments but rather resides and survives in an acidic phagolysosome.

Calibration