PubMed Health⌕ Search

PubMed · 9286802

Subretinal microsurgery with gradient index endoscopes.

Abstract

State-of-the-art subretinal surgery involves a standard three-port pars plana entry, followed by an iatrogenic retinotomy to access the subretinal space. Subretinal manipulations through a small retinotomy are made possible by specially designed instruments. As the surgeon looks through the vitreous cavity, all subretinal maneuvers are obscured by the overlying retina. Consequently, the surgeon is operating 'blindly' and has to rely on 'feeling' rather than direct visualization. Micro-endoscopic viewing systems are the ideal solution for visualization during subretinal surgery. Until now, such endoscopes were either too large for intraocular use or lacked sufficient resolution, especially at a short working distance. Recently, a gradient index (GRIN) endoscope was developed (Insight Instruments, Inc., Lake Mary, Fla., USA) combining a small diameter (0.89 mm, 20 gauge) and incorporating excellent optical resolution, even at extremely close working distances. After ballooning a limited part of the retina without creating a retinal hole, the 20-gauge GRIN endoscope can be introduced into the subretinal space through the sclera and choroid, posterior to the pars plana. Surgical instruments can then be introduced into the subretinal space through a second neighboring sclerotomy. Thus, subretinal surgery can be performed under direct endoscopic control. As a result of direct visualization, the surgeon may perform certain surgical procedures with greater accuracy, i.e., subretinal neovascular membranes may be dissected meticulously from the neurosensory retina and retinal pigment epithelium, minimizing damage to both structures. The feeding choroidal vessel can be identified and directly coagulated, which is usually very difficult during conventional subretinal surgery. Endoscopic subretinal surgery is thus a significant improvement over conventional methods, avoiding the need for a retinotomy and increasing the safety and facility of the surgery itself.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F H Koch, K P Luloh, A J Augustin, M S el Agha, H Guembel, C Ohrloff, W S Grizzard, M E Hammer, S Sinclair. 1997. Subretinal microsurgery with gradient index endoscopes.. https://doi.org/10.1159/000310809

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Two-photon fluorescence endoscopy with a micro-optic scanning head.

A major obstacle in the race to develop two-photon fluorescence endoscopy is the use of complicated bulk optics to transmit an ultrashort-pulsed laser beam and return the emitted fluorescence signal. We describe an all-fiber two-photon fluorescence microendoscope based on a single-mode optical fiber coupler, a microprism, and a gradient-index rod lens. It is found that the new endoscope exhibits an axial resolution of 3.2 microm and is capable of imaging transverse cross sections of internal cylindrical structures as small as approximately 3.0 mm in diameter. This device demonstrates the potential for developing a real-time diagnostic tool for biomedical research without the need for surgical biopsy and may find applications in photodynamic therapy, microsurgery, and early cancer detection.

Endoscopy↗

A case of complete resolution of mediastinal pseudocyst and pleural effusion by endoscopic stenting of pancreatic duct.

We report a case of a mediastinal pseudocyst with a pleural effusion that developed in a patient suffering from alcohol- related chronic pancreatitis. A 53-year-old man was admitted to another institution complaining of pleuritic chest pain and coughing. A chest X-ray revealed a pleural effusion with a collapse of the right middle and lower lobes. Pleural fluid taken by thoracentesis was exudative, and the patient was transferred to our institution. A CT scan showed a loculated cystic lesion in the mediastinum and pancreatic changes that were consistent with chronic pancreatitis. The endoscopic retrograde cholangiopancreatography (ERCP) findings were compatible with chronic pancreatitis showing severe pancreatic ductal stricture at the head with an upstream dilation and distal bile duct stricture. After a one week of treatment with fasting and octreotide without improvement, both pancreatic and biliary stents were placed endoscopically. After stenting, the pleural effusion and pseudocyst rapidly resolved. The stents were changed 3 months later, at which time a repeated CT demonstrated a complete resolution of the pseudocyst. Since the initial stenting, he has been followed up for 7 months and is doing well with no recurrence of the symptoms, but he will need to undergo regular stent changes. Overall, endoscopic pancreatic stenting appears to be a good option for managing selected cases of mediastinal pancreatic pseudocysts.

Endoscopy↗

Abnormal endoscopic pharyngeal and laryngeal findings attributable to reflux.

The symptom complex associated with acid-induced injury to the larynx is referred to as laryngopharyngeal reflux (LPR). Basing the diagnosis of LPR on patient symptoms or 24-hour dual-probe pH data may be inaccurate, as these diagnostic tests are restricted by limitations in both sensitivity and specificity. The clinician must have a thorough understanding of endoscopic findings associated with this disorder. The severity of laryngeal inflammation caused by acid and activated pepsin can be quantified. This article reviews the abnormal endoscopic pharyngeal and laryngeal findings that are attributable to reflux.

Endoscopy↗