PubMed Health⌕ Search

PubMed · 9291561

Second generation video imaging technique for assessing dermal exposure (VITAE System).

Abstract

Development of a second-generation video imaging technique for assessing occupational skin exposure (VITAE) is described, its performance evaluated, and new procedures for exposure quantification are presented. The current VITAE system has higher resolution in regard to both its picture element array and gray scale when compared with the prototype system. System performance was evaluated during extended field deployment: variability was 3-4% during data acquisition for individual worker evaluation session, and 10% over a 22-day study period. Variabilities attributable to subject positioning and image outlining procedures were 2.7 and 1.2%, respectively. Visual observations of fluorescent tracer deposition on skin were used to classify specific body regions as either exposed of unexposed, and two computer-based classification criteria were tested against the visual classification. These criteria were generally better at minimizing false negative and false positive classification; sensitivity and predictive value reached 95 and 99%, respectively, when analysis was preceded by presampling of a subset of images. Variability in skin pigmentation was found to have a substantial effect on fluorescent tracer qualification, leading to development of new calibration procedures. Standard curves were generated by spotting a range of tracer concentrations on volunteer subjects and quantifying fluorescence with the VITAE system. These data were then grouped either by subject or by the magnitude of the background signal of the unexposed skin. The ability to control for the effects of skin pigmentation was found to be comparable for these grouping methods, indicating that calibration curves can be developed without the creation of a unique curve for each subject.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R A Fenske, S G Birnbaum. 1997. Second generation video imaging technique for assessing dermal exposure (VITAE System).. https://doi.org/10.1080/15428119791012423

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Fermentation process tracking through enhanced spectral calibration modeling.

The FDA process analytical technology (PAT) initiative will materialize in a significant increase in the number of installations of spectroscopic instrumentation. However, to attain the greatest benefit from the data generated, there is a need for calibration procedures that extract the maximum information content. For example, in fermentation processes, the interpretation of the resulting spectra is challenging as a consequence of the large number of wavelengths recorded, the underlying correlation structure that is evident between the wavelengths and the impact of the measurement environment. Approaches to the development of calibration models have been based on the application of partial least squares (PLS) either to the full spectral signature or to a subset of wavelengths. This paper presents a new approach to calibration modeling that combines a wavelength selection procedure, spectral window selection (SWS), where windows of wavelengths are automatically selected which are subsequently used as the basis of the calibration model. However, due to the non-uniqueness of the windows selected when the algorithm is executed repeatedly, multiple models are constructed and these are then combined using stacking thereby increasing the robustness of the final calibration model. The methodology is applied to data generated during the monitoring of broth concentrations in an industrial fermentation process from on-line near-infrared (NIR) and mid-infrared (MIR) spectrometers. It is shown that the proposed calibration modeling procedure outperforms traditional calibration procedures, as well as enabling the identification of the critical regions of the spectra with regard to the fermentation process.

Calibration↗

Particle sizing with a fast polar nephelometer.

We reported previously the design of a polar nephelometer that uses a rotational confocal imaging setup to enable fast scanning of the scattering phase function within a field of view of 55 degrees . The full dynamic range of the detection system can be used by increasing the signal-to-noise ratio by means of averaging successive scans. The calibration of the angular response of the instrument is achieved by obtaining the transfer function of the optical detection system using Rayleigh scatterers. Accurate particle sizing of individual polystyrene spheres (ranging from 1.5 to 9 micro m in diameter) in aqueous suspension is achieved by maximizing a correlation coefficient between precalculated tables of Mie phase functions and data obtained from the polar nephelometer. Good correlation is achieved between experimental and theoretical data, proving the functioning of the instrument as a fast and convenient particle sizer.

Calibration↗

Online standard additions calibration of transient signals for inductively coupled plasma mass spectrometry.

An online standard additions calibration method for transient signals in ICPMS is demonstrated in which a small volume of standard is injected as a spike into the sample/carrier stream, overlaying the analyte peak. This technique provides the advantages of conventional standard additions but requires only a single sample run. The method corrects for matrix effects and is suitable for transient signals in which the severity of the matrix effect changes over the analyte peak. The method uses a peak-fitting program to determine the area of the underlying peak and is shown to be effective for the determination of trace metal concentrations in both a high ionic strength matrix and in a biological matrix (urine). Eight analytes with concentrations in the range of 0.82-233.2 mug L-1 in urine were simultaneously determined using a standard spiking solution of 75 mug L-1 injected through a 100-muL loop. The measured concentrations for analytes free of spectral interferences agreed with the certified values, and the precision achieved was comparable to that achieved by the certifying agency. Using a conventional cross-flow nebulizer and Scott-type spray chamber, the accuracy obtained for online standard additions calibration was within 2%, and the precision was within 5%.

Calibration↗