Man-machine interfaces in computer assisted surgery.

Abstract

The clinical potential of computer assisted surgery (CAS) has been more and more widely acknowledged since CAS systems have been introduced into the operating room (OR) theater. Especially the improvements in safety and accuracy are remarkable and strengthen the ties between surgeons and engineers. Tumor stereotaxis was introduced to neurological surgery in the early 1980s, and currently systems with and without robotic navigation are in use for specific medical indications. Recently, solutions for computer assisted orthopedic surgery were developed and applied to various anatomical regions. However, with the establishment of CAS in vivo, a new complex of problems, which was not present in the laboratory setup, was introduced: the man-machine interface. Currently, the complexity of available CAS systems requires the presence of at least one system engineer (often called the "operator") in the OR. As a consequence, there is no possibility for direct communication between the surgeon and the machine or software. Most of the program steps involved in CAS and choices to be made intraoperatively have to be transferred to the software by means of communication of the surgeon with the operator. Particularly, the establishment of a relation between the virtual object (i.e., a medical image) and the surgical object (i.e., the patient), often denoted as "matching" or "skeletal registration," requires intensive interaction of the surgeon with the computer. A literature survey revealed that no CAS system in clinical use exists without a system engineer or a comparable person, and our clinical experience indicated that the matching process is a weak point in most systems. Because it appears to be contradictory to cost-reduction efforts in health care to have a highly paid specialist in the OR, this research evaluates strategies to facilitate the man-machine interface with the final goal of establishing a direct control of the system by the surgeon or the medical personnel traditionally present at surgery. Options to be investigated include 1) a CAS control panel (virtual keyboard) as an integrated component of the existing navigation system and 2) introduction of a commercial voice-recognition system. The implementation of these strategies into the existing CAS setup at the Department of Orthopaedic Surgery at the Inselspital (University of Bern) and clinical experience gained are reported.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Visarius, J Gong, C Scheer, S Haralamb, L P Nolte. 1997. Man-machine interfaces in computer assisted surgery.. https://doi.org/10.1002/(sici)1097-0150(1997)2%3A2%3C102%3A%3Aaid-igs3%3E3.0.co%3B2-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Linear servo-controlled pressure generator for forced oscillation measurements.

In respiratory input impedance measurements, the low-frequency range contains important clinical and physiological information. However, the patient's spontaneous ventilation can contaminate the data in this range, leading to unreliable results. Unbiased estimators are a good alternative to overcome this problem, provided that the generator is considered linear. This condition is not fulfilled by most existing generators as they are based on loudspeakers, which have strong nonlinearities. The present work aims to contribute to the solution of this problem, and describes a pressure generator that minimises the nonlinearities by an optical sensor placed in a position feedback loop. The static evaluation shows a high linearity for the optical system. The well known frequency response of pressure transducers is used in the dynamic evaluation of the instrument. The analysis of the generator shows that the use of position feedback improved the frequency response. The total harmonic distortion (THD) measurement shows that closed loop resulted in an effective decrease in the nonlinearities. The reduction of THD achieved by the servo-controlled generator can contribute to the practical implementation of the unbiased estimators, increasing the reliability of the impedance data, especially in the low-frequency range. This system is compared with conventional generators and with another servo-controlled system.

Biomedical Engineering

Exercise tricycle for paraplegics.

The work describes a tricycle that can be used by paraplegics without assistance. Paraplegics can get on and off the tricycle independently, using hydraulic adjustment of the saddle height. The two rear wheels can be swivelled with adjustable hydraulic damping, which avoids the stability problems of a standard tricycle when riding around bends. The principal driving power is assumed to be provided by functional electrical stimulation of the femoral muscles. A hub motor is integrated in the front wheel to increase the radius of action, as additional drive for cycling up gradients and in case muscle force is not sufficient. The desired drive power is adjusted by a throttle grip on the handlebar. The percentage of motor power can also be adjusted. The force applied to the pedal, the absolute angular position of the crank, and the angular velocity of the front wheel are continuously measured by a force measurement pedal and a goniometer. Based on this information, the motor and the functional electrical stimulation of the legs are controlled.

Biomedical Engineering