PubMed Health⌕ Search

PubMed · 9307958

Implementation of enhanced dynamic wedge using Theraplan.

Abstract

The article discusses how to use the standard utility program on Theraplan to create physical wedges which are equivalent to each of the enhanced dynamic wedges. The user must first create segmented treatment tables for each wedge, using a spreadsheet, and then convert these tables to equivalent thicknesses of an arbitrary wedge material. These thicknesses are then supplied to Theraplan. The paper discusses the agreement achieved between Theraplan and measured data, and the quality assurance procedures which should be adopted.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J A Cramb, T L Ackerly. 1997. Implementation of enhanced dynamic wedge using Theraplan.. https://doi.org/10.1016/s0958-3947(97)00025-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The need for rotational margins in intensity-modulated radiotherapy and a new method for planning target volume design.

PURPOSE: The effect of rotational errors on the coverage of clinical target volumes (CTVs) is examined. A new planning target volume (PTV) construction that considers the individual paths traced by movements of the target boundary points is developed. METHODS AND MATERIALS: A standard uniform margin expansion was compared with a PTV constructed from the space swept out by a concave moving target. A new method formed the PTV by aggregating the separate convex hulls taken of the positions of the individual target boundary points in a sampling of CTV displacements. RESULTS: A 0.5-cm uniform margin adequate for translations was inadequate given CTV rotation about a fixed off-center axis. A PTV formed of the target's swept-out area was 22% smaller than needed for coverage by a uniform margin, but computationally is not readily extended to translations combined with rotations about a shifting axis. Forming instead the union of convex hulls of the boundary points in a sampling of CTV displacements represented these movements in the PTV design and retained the target's concave shape. CONCLUSIONS: Planning target volumes should accommodate target rotation. The union of convex hulls of the boundary point positions in a sampling of displacements can effectively represent multiple sources of deviations while preserving target concavities.

Radiotherapy Planning, Computer-Assisted↗

Assessment of the acceptability of the Elekta multileaf collimator (MLC) within the Corvus planning system for static and dynamic delivery of intensity modulated beams (IMBs).

The sliding window technique used for static and dynamic segmentation of intensity modulated beams is evaluated. Dynamic delivery is preferred since the resulting distributions correspond better with the calculated distributions, the treatment beam is used more efficiently and the delivery is less sensitive to small variations in the accuracy of the multileaf collimator (MLC).

Radiotherapy Planning, Computer-Assisted↗

A simple and reliable method to simulate multileaf-plans.

To combine conformity of the irradiation with time effectiveness during treatment, the use of multileaf collimators has become more and more common. However, the simulation of the leaf positions is rather difficult compared with metal blocks. We developed a new method, utilizing an acrylic template in which the contour produced by the leaves is machined in the form of a 1 mm groove by a computerized numerically controlled milling machine. This template is then inserted into a mount attached to the simulator. The main advantages are the errorfree, direct communication from the therapy planning system to the milling machine via a network, the possibility to transfer the contour to the skin, and the documentation on the simulation film. The use of templates is reliable and, e.g. the costs of the materials are lower than for block simulation.

Radiotherapy Planning, Computer-Assisted↗