PubMed Health⌕ Search

PubMed · 9312701

[New developments in joint surgery].

Abstract

The treatment of joint injuries has seen a marked development in the last years. The surgical trauma of articular reconstruction was reduced and our deeper understanding of the mechanism of connective tissue healing influenced the rehabilitation program after joint injuries significantly. Indirect soft-tissue sparing reduction techniques can be applied to most joint fractures and improved fixation techniques using intraoperative fluoroscopy or arthroscopy allow to avoid vast exposures of the joint. The process of ligament healing requires joint movement and a certain stress to the healing tissue in order to achieve optimum scar strength, stiffness and remodeling. Immobilisation thus should be avoided completely after ligament injuries and certain lesions can be treated non-operatively with a high success rate (MCL rupture, ankle sprain, elbow dislocation). In other injuries, surgery should stabilize the joint thus allowing functional rehabilitation (cruciate ligament tears, shoulder dislocation).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Lobenhoffer, M Blauth, T Pohlemann, H Thermann, H Tscherne. 1997. [New developments in joint surgery].. https://doi.org/10.1007/s001320050109. https://pubmed.health/record/pubmed%3A9312701/new-developments-in-joint-surgery

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite PubMed Health by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Safety evaluation of large external fixation clamps and frames in a magnetic resonance environment.

Large orthopedic external fixation clamps and related components were evaluated for force, torque, and heating response when subjected to the strong electromagnetic fields of magnetic-resonance (MR) imaging devices. Forces induced by a 3-Tesla (T) MR scanner were compiled for newly designed nonmagnetic clamps and older clamps that contained ferromagnetic components. Heating trials were performed in a 1.5 and in a 3 T MR scanner with two assembled external fixation frames. Forces of the newly designed clamps were more than a factor 2 lower as the gravitational force on the device whereas, magnetic forces on the older devices showed over 10 times the force induced by earth acceleration of gravity. No torque effects could be found for the newly designed clamps. Temperature measurements at the tips of Schanz screws in the 1.5 T MR scanner showed a rise of 0.7 degrees C for a pelvic frame and of 2.1 degrees C for a diamond knee bridge frame when normalized to a specific absorption rate (SAR) of 2 W/kg. The normalized temperature increases in the 3 T MR scanner were 0.9 degrees C for the pelvic frame and 1.1 degrees C for the knee bridge frame. Large external fixation frames assembled with the newly designed clamps (390 Series Clamps), carbon fiber reinforced rods, and implant quality 316L stainless steel Schanz screws met prevailing force and torque limits when tested in a 3-T field, and demonstrated temperature increase that met IEC-60601 guidelines for extremities. The influence of frame-induced eddy currents on the risk of peripheral nerve stimulation was not investigated.

External Fixators↗