PubMed Health⌕ Search

PubMed · 9342000

The inseparable triad: analytical sensitivity, measurement uncertainty, and quantitative resolution.

Abstract

The formal definition of sensitivity associates the term with the change in the response of a system for a small change of the stimulus causing the response, i.e., the ratio of the response of a system to the stimulus causing it. One interpretation of sensitivity associates the rate of change of the response for a small change of the stimulus as the slope of a calibration plot of response vs stimulus. An alternative interpretation associates sensitivity with the smallest value of the stimulus that can be resolved with a given degree of confidence, i.e., the detection limit. Applications of the first usage to analytical chemistry date at least to the beginning of this century; applications of the second interpretation are of more recent origin. The accompanying paper argues in favor of the second interpretation on the basis that, among other things, the "slope" interpretation conflicts with the formal definition of sensitivity and is meaningless as a descriptor of the performance of a measuring system. In this paper I offer arguments to support my belief that the slope definition of sensitivity is consistent with both formal definitions and accepted usage in analytical chemistry and, more importantly, that it is an invaluable descriptor of one of the most important characteristics of any analytical method. I include information to support my belief that proper use of the slope definition yields much more information than is available in the "detection limit" interpretation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H L Pardue. 1997. The inseparable triad: analytical sensitivity, measurement uncertainty, and quantitative resolution.. https://pubmed.ncbi.nlm.nih.gov/9342000/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Lab-on-a-chip devices for global health: past studies and future opportunities.

A rapidly emerging field in lab-on-a-chip (LOC) research is the development of devices to improve the health of people in developing countries. In this review, we identify diseases that are most in need of new health technologies, discuss special design criteria for LOC devices to be deployed in a variety of resource-poor settings, and review past research into LOC devices for global health. We focus mainly on diagnostics, the nearest-term application in this field.

Clinical Chemistry Tests↗

A note on the use of outlier criteria in Ontario laboratory quality control schemes.

OBJECTIVES: This paper examines the pitfalls that arise when an outlier is assessed using a criterion based on a fixed multiple of the standard deviation rather than an established statistical test. Although the former approach is statistically invalid, it is the favored method for identifying outliers in Ontario laboratory quality control protocols. DESIGN AND METHODS: Computer simulations are used to calculate the probability of a false positive result (classifying a valid observation as an outlier) when outlier criteria based on fixed multiples of the standard deviation are applied to samples containing no outliers. RESULTS: The estimated probability of a false positive result is tabulated over various sample sizes. Outlier criteria based on fixed multiples of the standard deviation are shown to be highly inefficient. CONCLUSIONS: This work presents arguments for discontinuing the widespread practice of using outlier criteria based on fixed multiples of the standard deviation to identify outliers in univariate samples.

Clinical Chemistry Tests↗

Sample to sample carryover: a source of analytical laboratory error and its relevance to integrated clinical chemistry/immunoassay systems.

BACKGROUND: Integrated systems that combine clinical chemistry and immunoassay analyzers are used routinely. Sample to sample carryover is an inherent risk and can cause erroneously high patient test results for immunoassays. IVD manufacturers and laboratories must be aware of this phenomenon and guard against it. METHODS: We used a sample carryover protocol that directs the clinical chemistry module to process samples with very high immunoassay analyte concentrations followed by samples with very low concentrations for the same analyte. Low concentration samples were then tested by the immunoassay module to determine if the clinical chemistry module caused primary sample tube to primary sample tube carryover of the immunoassay analyte. RESULTS: Sample carryover was assessed on the Abbott ci8200 for HBsAg, AFP, beta-hCG, and PSA. Observed HBsAg carryover met the design specification of <0.1 ppm. Carryover for the other analytes was <0.1 ppm or below the assay limit of detection. CONCLUSIONS: IVD manufacturers must design integrated systems to minimize primary specimen tube carryover and avoid analytical laboratory error that can impact patient safety. Carryover testing is difficult for clinical laboratories to perform in order to verify system performance. Laboratories must consider the potential for specimen carryover and its impact on results whether moving primary sample tubes between separate analyzers or using an integrated system.

Clinical Chemistry Tests↗