PubMed Health⌕ Search

PubMed · 9400637

Spinal instrumentation with a low complication rate.

Abstract

BACKGROUND: Spinal instrumentation has become an increasing part of the armamentarium of neurosurgery and neurosurgical training. For noncontroversial indications for spine fusion the arthrodesis rate seems to be better. For both noncontroversial and controversial indications, the reported complication rate with spinal instrumentation tends to be greater than that with noninstrumented spine surgeries. These reported complications include a 2-3% neurologic injury rate, 3-45% reoperation rate for implant failure, and inflection rates of 5-10%. Therefore, we report on 299 cases that have undergone spinal instrumentation placed exclusively by neurosurgeons with a very low complication rate. METHODS: Two hundred ninety-nine consecutive spinal instrumentation cases performed exclusively by neurosurgeons at Indiana University Medical Center were analyzed for complications related to spinal instrumentation. The spinal instrumentation placed consisted of 195 anterior cervical locking plates, 22 cases of posterior cervical instrumentation, 9 cases of combined anterior locking plates with posterior cervical instrumentation, 14 anterior thoracolumbar plates, 51 posterior thoraco-lumbar instrumentation cases, and 8 combined anterior/posterior thoracolumbar instrumentation cases. RESULTS: The mean follow-up is 40 months (6-95). There was one perioperative death unrelated to the spinal instrumentation. There were no neurologic injuries and there has been no hardware infection to date. There were two dural tears, three superficial wound infections, and three minor wound breakdowns successfully treated. Hardware complications included three cervical plate/screw extrusions reoperated, one cervical plate fracture reoperated, one posterior cervical screw backout not reoperated, one case of broken pedicle screw not reoperated, one vertebral body failure not reoperated, and one posterior rod case reoperated for excessive rod length and protrusion. The overall complication rate attributable to placement of spinal instrumentation was 10/299 (3%) with a reoperation rate of 2%. The arthrodesis rate was 298/299 (99%). CONCLUSION: The complication rate for using spinal instrumentation can be less than previously reported. Lessons learned and discussed should reduce the rate even more. Spinal instrumentation is a safe and useful adjunct to fusion in treating degenerative, traumatic, infectious, and neoplastic diseases of the spine.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S A Shapiro, W Snyder. 1997. Spinal instrumentation with a low complication rate.. https://doi.org/10.1016/s0090-3019(97)00296-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Stacked plating for metadiaphyseal fractures of the distal radius: a technique report.

Combined injuries of the distal radius and shaft are rare, are usually caused by high energy, and pose a surgical dilemma. Surgical tactics and implants that are routinely used either for isolated fractures of the distal radius or for fractures of the radial shaft are often not applicable for this combined injury. We describe a technique of dual-stacked plating for these metadiaphyseal fractures and its use in two patients.

Bone Plates↗

Plate fixation of olecranon osteotomies.

The management of intra-articular distal humeral fractures remains a difficult surgical problem. Although an olecranon osteotomy provides excellent exposure for management of these fractures, a number of complications can occur after the creation and repair of the osteotomy including nonunion, malunion, hardware failure, and pain secondary to prominent hardware. In an effort to reduce the incidence of these complications, the senior authors now use contoured 3.5 mm reconstruction plates for the fixation of their apex-distal chevron olecranon osteotomies. Two surgeons at a single institution used this technique of exposure on a series of 17 consecutive patients with intra-articular distal humerus fractures between 1996 and 1999. In this series, all osteotomies united. There was one complication related specifically to the osteotomy: one of the screws in the plate penetrated the proximal radioulnar joint, interfering with forearm rotation; a second procedure was required to shorten the screw. Only one of the 17 patients requested plate removal during the 32 month (average) follow-up period. Plate fixation of olecranon osteotomies using a 3.5 mm reconstruction plate provides a construct with predictable healing and few complications. The overall results using this technique are comparable with other reported methods in the literature.

Bone Plates↗