PubMed Health⌕ Search

PubMed · 9551075

Duplex-directed vena caval filter placement: report of initial experience.

Abstract

BACKGROUND: Fluoroscopy, cost, and patient transport contribute to difficulties occasionally associated with the placement of vena caval filters. Follow-up data in the literature document the use of duplex ultrasonography in visualizing the filter and determining caval patency. Filter placement at the bedside or in the vascular laboratory with duplex ultrasonography may simplify this common procedure. We have attempted to define the feasibility of this method. METHODS: Patients referred to the vascular surgery service for vena caval interruption were evaluated for ability to visualize the renal veins and inferior vena cava. Location of renal veins, maximum diameter of the vena cava, and presence or absence of thrombus were documented. If visualization was adequate, placement was performed at the bedside for patients in intensive care or in the vascular laboratory for nonmonitored patients. The initial 10 patients and subsequent patients in whom there was a question of adequate deployment underwent completion abdominal roentgenography. Patient follow-up was difficult. Duplex ultrasonography was used to assess migration, thrombus adherent to the filter, and vena caval patency. Patients in whom filter placement was prophylactic were given anticoagulants at the discretion of the primary physician. Inadequate visualization or vena caval size greater than 28 mm prompted fluoroscopic placement of the vena caval filter, because only Greenfield titanium filters were used in the study. RESULTS: Twenty-nine patients were referred for vena caval interruption. Inadequate visualization occurred in four obese patients, and filters were placed by fluoroscopy. There were no vena caval measurements greater than 24 mm. Twenty-five filters were placed without technical difficulty. One filter tilted into the right renal vein, requiring a suprarenal filter placed by fluoroscopy. Patient retrieval for follow-up has been difficult, but by ultrasonography there has been one vena caval thrombosis and no major filter migration. There have been no reported pulmonary emboli other than the one patient with initial tilt of the filter. CONCLUSIONS: Placement of vena caval filters is feasible with duplex ultrasonography. Visualization is the only limiting condition to placement and occurs rarely. Reducing the need for fluoroscopy, lowering costs, and not needing to transport the critically ill patient support the use of this system. Intravascular ultrasonography in selected patients may eliminate the need for fluoroscopic placement of vena caval filters.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D F Neuzil, C L Garrard, R A Berkman, R Pierce, T C Naslund. 1998. Duplex-directed vena caval filter placement: report of initial experience.. https://pubmed.health/record/pubmed%3A9551075/duplex-directed-vena-caval-filter-placement-report-of-initial-experience

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite PubMed Health by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Population and patient-specific target margins for 4D adaptive radiotherapy to account for intra- and inter-fraction variation in lung tumour position.

In this work, five 4D image-guidance strategies (two population, an offline adaptive and two online strategies) were evaluated that compensated for both inter- and intra-fraction variability such as changes to the baseline tumour position and respiratory pattern. None of the strategies required active motion compensation such as gating or tracking; all strategies simulated a free-breathing-based treatment technique. Online kilovoltage fluoroscopy was acquired for eight patients with lung tumours, and used to construct inter- and intra-fraction tumour position variability models. Planning was performed on a mid-ventilation image acquired from a respiration-correlated CT scan. The blurring effect of tumour position variability was included in the dose calculation by convolution. CTV to PTV margins were calculated for variability in the cranio-caudal direction. A population margin of 9.0 +/- 0.7 mm was required to account for setup error and respiration in the study population without the use of image-guidance. The greatest mean margin reduction was introduced by the offline adaptive strategy. A daily online correction strategy produced a small reduction (1.6 mm) in the mean margin from the offline strategy. Adaptively correcting for an inter-fraction change in the respiratory pattern had little effect on margin size due to most patients having only small daily changes in the respiratory pattern. A daily online correction strategy would be useful for patients who exhibit large variations in the daily mean tumour position, while an offline adaptive strategy is more applicable to patients with less variation.

Fluoroscopy↗

Patient and staff dosimetry in vertebroplasty.

STUDY DESIGN: Eleven vertebroplasty operations were studied in terms of radiation dose. OBJECTIVE: Doses to patients and staff associated with vertebroplasty were measured. Occupational doses were compared with the annual dose limits, and the effectiveness of the used radiation protection means was estimated. Patient dose was estimated by means of both surface and effective dose, and the radiation-induced risk was evaluated. SUMMARY OF BACKGROUND DATA: Vertebroplasty is a recent minimally invasive technique for the restoration of vertebral body fractures. It involves fluoroscopic exposure, and so, it demands dose measurements for both patient and staff exposed to radiation. METHODS: Thermoluminescent dosimeters (TLDs) were placed on the medical personnel and the effective dose was derived. Slow films were placed to patients' skin to measure entrance surface dose. Furthermore, a Rando phantom loaded with TLDs was irradiated under conditions simulating vertebroplasty, in order to estimate effective dose to the patient. RESULTS: Mean fluoroscopy time was 27.7 minutes. Patient's mean skin dose was 688 mGy, while effective dose was calculated to be 34.45 mGy. It was estimated that the primary operator can perform about 150 vertebroplasty operations annually without exceeding the annual dose constraints, whereas occupational dose can be reduced by 76% using mobile shielding. CONCLUSIONS: Measures have to be taken to reduce patient's skin dose, which, in extreme cases, may be close to deterministic effects threshold. The highest dose rates, recorded during the procedure, were found for primary operator's hands and chest when no shielding was used.

Fluoroscopy↗

An inter-hospital comparison of patient dose based on clinical indications.

Patient dose is usually estimated for a single radiographic projection or computed tomography (CT) series. In this study, patient dose was calculated for predefined clinical indications (24 radiography, 11 CT). Members of the radiology staff of each of 11 hospitals were trained in dose measurement and calculation techniques. Based on clinical indications participants decided on imaging protocols and calculated cumulative effective dose for a complete examination. Effective dose ranged from <1 microSv to 0.6 mSv for examinations with radiographs and from 0.2 to 12 mSv for CT scans. Differences in the imaging protocols contributedd to a substantial variation in patient dose. For mammography, average glandular dose (AGD) was estimated for 32-, 53- and 90-mm compressed breast thicknesses, with a median value of 0.74, 1.74 and 3.40 mGy, respectively. The results presented here demonstrate that a pragmatic choice of dosimetry methods enables local staff to estimate effective dose. The inclusion of imaging protocols in the dose surveys provided a broader view on the variations in patient dose between hospitals.

Fluoroscopy↗