PubMed Health⌕ Search

PubMed · 9556123

Decelerating flow ventilation effects in acute respiratory failure.

Abstract

PURPOSE: The purpose of this article is to analyze the effect of a pressure-regulated volume-controlled ventilation mode on lung mechanics and gas exchange in patients with acute respiratory failure. MATERIALS AND METHODS: We ventilated 10 patients with two pressure-limited modes: pressure-controlled ventilation (PC) and pressure-regulated volume-controlled ventilation (PRVC) in random order, for 1 hour each. Patients were stabilized on volume-controlled ventilation (VC) for 30 minutes before, between, and at the end of PC and PRVC to reach baseline conditions. At the end of every VC period and at 30 and 60 minutes of PC and PRVC, respiratory mechanics, gasometrics, and hemodynamic parameters were collected. RESULTS: We found no significant differences between the three VC periods. Comparing VC with the two pressure-limited ventilation modes, peak pressure decreased from 29.4+/-9.1 cm H2O (VC) to 25.9+/-8.4 (PC 60 minutes) and 26.1+/-8.2 (PRVC 60 minutes), and PaCO2 decreased significantly from 38.6+/-3.1 mm Hg (VC) to 36.7+/-2.8 (PC 60 minutes) and 36.8+/-2.9 (PRVC 60 minutes). CONCLUSIONS: Pressure-limited ventilation allows mechanical ventilation for the same tidal volume as VC but results in a lower peak inspiratory pressure and a slightly lower PaCO2. The mechanism responsible for this gas exchange effect is unknown but is probably related to a better air distribution of the decelerated flow. The clinical relevance of this phenomenon remains to be established.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Alvarez, M Subirana, S Benito. 1998. Decelerating flow ventilation effects in acute respiratory failure.. https://doi.org/10.1016/s0883-9441(98)90025-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗