PubMed HealthSearch

PubMed · 9620040

Automated screening.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D C Wilbur. 1998. Automated screening.. https://pubmed.ncbi.nlm.nih.gov/9620040/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

On-line coupling of microdialysis sampling with liquid chromatography for the determination of peptide and non-peptide leukotrienes.

An automated on-line sampling method was developed using microdialysis as the simultaneous sampling and sample pre-treatment technique. The extraction fraction values of microdialysis probes sampling different eicosanoids were investigated. The impact of cyclodextrins in the perfusion liquid used for sampling hydrophobic eicosanoids in biological systems was also studied. The total time for one analysis was 7.6 min allowing seven measurements per hour for monitoring kinetic changes in biological systems.

Autoanalysis

Comparison of simplified methods for pesticide residue analysis. Use of large-volume injection in capillary gas chromatography.

The combination of manual and automated extraction procedures using low sample volumes (5-50 ml) with large-volume oncolumn injection (LVI) (200 microliters) in capillary gas chromatography with flame photometric detection (GC-FPD) has allowed the determination of 16 organophosphorus pesticides in clean water samples at the low ng l-1 level with an important simplification in the sample preparation step. A simple and fast offline liquid-liquid microextraction procedure (2-5 ml water/l ml methyl tert.-butyl ether) has been applied to spiked groundwater samples (containing 0.5 ng of each pesticide) with good recoveries (over 80%) and precision (better than 10%), giving detection limits between 5 and 100 ng l-1 using 200 microliters injections in the GC-FPD system. The application of an inline automated liquid-liquid microextraction-LVI-GC procedure (2 ml water/2 ml methyl tert.-butyl ether: injection of 200 microliters in GC-FPD) using the autosampler ASPEC XL led to lower recoveries (> 50%) as a result of the low efficiency for mixing organic and aqueous phases, although with very satisfactory coefficients of variation (lower than 7%) and detection limits between 20 and 200 ng l-1. Manual and automated solid-phase extraction procedures using the well known C18 cartridges and the new Oasis HLB have been applied to groundwater samples (5-50 ml) spiked with 1 ng of each pesticide. Results obtained for both the manual and the automated procedures were satisfactory (recoveries over 80%) and the limits of detection for 50 ml sample volume ranged from 1 to 6 ng l-1.

Autoanalysis

Automated determination of phenylcarbamate herbicides in environmental waters by on-line trace enrichment and reversed-phase liquid chromatography-diode array detection.

A fully automated liquid chromatographic method using on-line trace-enrichment, gradient elution and diode array detection is described for the trace-level determination of several phenylcarbamate herbicides, such as carbetamide, propham, desmedipham, phenmedipham, chlorbufam and chlorpropham, in environmental water samples. In this work, two different enrichment pre-columns have been assayed, a 5.8 x 4.6 mm I.D., 10 microns ODS Prelute cartridge and a 10 x 2 mm I.D. cartridge filled with 10 microns PRP-1 polymer, both coupled to a 150 x 4.6 mm I.D. analytical column filled with 5 microns ODS. Using the C18 pre-column, up to 50 ml of water sample could be percolated without peak broadening of any compound. However, a lack of reproducibility was observed in the case of carbetamide, the most polar analyte, after performing recovery experiments by percolating drinking and surface water samples spiked at several levels (0.5 and 4 micrograms l-1). On the other hand, the PRP-1 pre-column allowed the enrichment up to 100 ml of water sample with satisfactory results for every compound, including carbetamide. The procedure was validated by recovery experiments in environmental water samples spiked at 0.2 and 1 microgram l-1 yielding average recoveries between 84-108% with relative standard deviations in the range 2-12%. Detection limits as low as 0.04 microgram l-1 were achieved. It was observed that desmedipham and phenmedipham degraded rapidly in the environmental water samples as showed the degradation studies performed along 24 h in drinking and surface waters spiked at 4 micrograms l-1. Although the standard mixture, prepared in HPLC water, was stable for around one week, in the environmental water matrices more than 95% of each herbicide degraded after 6 h, and new chromatographic peaks corresponding to the degradation products were detected.

Autoanalysis