PubMed Health⌕ Search

PubMed · 9645670

Effects of intake function shape on internal dose estimations.

Abstract

The estimated values of time-integrated dose equivalent are different if one assumes continuous intake, such as is the case for longer-term environmental exposures, instead of instantaneous intake, which is the assumption made for most standardized computational procedures. This paper presents the solutions of the first order kinetic equations for the ICRP 30 models of the respiratory system (RS) and the gastrointestinal tract (GI) for continuous activity intake. These solutions are applied to compute the cumulated number of disintegrations for different intake and integration times in order to show the effects of the assumptions of instantaneous intake vs. continuous intake on dose. For pulmonary clearance class D compounds instantaneous and continuous intake functions result in dose estimations agreeing to within 10% (when normalized to total intake) for integration times larger than 8 d for both RS and GI, for the case of radionuclides with radiological half-lives ranging between 8 d and 10(7) y. For 141Ce (class W) for both RS and GI the temporal intake function affects the dose by less than 10% for integration times greater than 280 d. In this case, the results for GI are less sensitive to the type of intake assumed than those for RS: the ratio of the number of transformations with the two intake assumptions has values of 0.8 or less for intake times of less than 7 d for GI and for intake times of less than 153 d for RS. For radionuclides such as 89Sr and 90Sr (class Y), the magnitude of the dose is very sensitive to the assumption made regarding the intake and has a strong dependence on the radionuclide half-life: for a 10% accuracy in dose evaluation for a continuous intake treated as instantaneous, the integration time must be greater than 650 d for 89Sr and 18,000 d for 90Sr. For all cases studied, the assumption of instantaneous intake overestimates the integrated dose for a continuous intake. More accurate internal dose evaluations may be made by consideration of the intake function shape when dose integration times less than approximately 10 y are of interest and non-instantaneous intakes are believed to have occurred.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Manuca, K J Kearfott. 1998. Effects of intake function shape on internal dose estimations.. https://doi.org/10.1097/00004032-199807000-00013

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Model for estimating population impacts averted through the remediation of contaminated soil.

This is the second in a series of papers that discuss methodologies being developed and employed by the U.S. Environmental Protection Agency in support of its decisions on cleanup levels for radioactively contaminated sites that are to be remediated and released for public use. It describes a model, CU-POP, designed by the U.S. Environmental Protection Agency to obtain estimates of the potential collective radiological health impacts over specific periods of time (100, 1,000 and 10,000 y following cleanup), both on and off site, due to residual radioactive materials in on-site soil. Collective doses and risks are linear in population density for the direct exposure, dust and indoor radon inhalation, and soil ingestion pathways; it is assumed that specific fractions of all food grown and all groundwater pumped at a site are consumed by on- and off-site populations. The model was developed for application to a set of hypothetical "reference" sites; its testing on a simple generic site is discussed briefly here.

Inhalation Exposure↗