PubMed · 9652516

Ultrasound contrast agents: basic principles.

Abstract

INTRODUCTION: Ultrasonography lacked substances to be administered to patients to improve or increase the diagnostic yield, which is peculiar considering that contrast agents have long been used with all the other imaging techniques. Fortunately some contrast agents, most of them consisting in gas microbubbles, have been recently introduced for ultrasound imaging too: this review will focus on their history, behavior, current applications and future developments. Echocontrast agent research is in progress and many new agents are expected to be marketed this and next year, to be added to Levovist by Schering AG (Berlin, Germany), to enhance the ultrasound signal safely and effectively. No definitive conclusions can be drawn yet on the actual merits of each contrast agent, but all of them seem to be both effective and safe, meaning that their future success will depend on the relative cost-effectiveness and peculiarities. THE BASIC PRINCIPLES OF ECHOCONTRAST AGENTS: The microbubbles act as echo-enhancers by basically the same mechanism as that determining echo-scattering in all the other cases of diagnostic ultrasound, namely that the backscattering echo intensity is proportional to the change in acoustic impedance between the blood and the gas making the bubbles. The different acoustic impedance at this interface is very high and in fact all of the incident sound is reflected, even though not all of it will of course go back to the transducer. But the acoustic wave reflection, though nearly complete, would not be sufficient to determine a strong US enhancement because the microbubbles are very small and are sparse in the circulation. Moreover, reflectivity is proportional to the fourth power of a particle diameter but also directly proportional to the concentration of the particles themselves. SECOND HARMONIC IMAGING: As we said above, the microbubbles reached by an ultrasound signal resonate with a specific frequency depending on microbubble diameter. However, the main resonance frequency is not the only resonance frequency of the bubble itself and multiple frequencies of the fundamental one are emitted, just like in a musical instrument. These harmonic frequencies have decreasing intensity, but the second frequency, known as the second harmonic, is still strong enough to be used for diagnostic purposes. The theoretical advantage of the harmonic over the fundamental frequency is that only contrast agent microbubbles resonate with harmonic frequencies, while adjacent tissues do not resonate, or else their harmonic resonation is very little. Thus, using a unit especially set to produce ultrasounds at a given frequency (3.5 MHz) and receive an ultrasound signal twice as powerful (7 MHz) it will be possible to show the contrast agent only, without any artifact from the surrounding anatomical structures, with a markedly improved signal-to-noise ratio. A similar effect to digital subtraction in angiography can thus be obtained, even though through a totally different process. Moreover, second harmonic imaging permits to show extremely small vessels (down to 40 microm) with very slow flow, which would be missed with a conventional method. B-mode imaging can also depict the microbubbles in the myocardium suppressing nearly all the artifacts from cardiac muscle motion. Recently a peculiar behavior of microbubbles has been observed which may permit contrast agent detection even in capillaries. This method is variously known as sonoscintigraphy, loss of correlation, stimulated acoustic emission and transient scattering. The contrast agent microbubbles reached by an ultrasound beam powerful enough explode producing a strong and very short backscatter echo which is read by the unit as a Doppler signal and results in a color pixel where the individual microbubble exploded. CONCLUSIONS: The microbubble contrast agents developed and introduced as safe and effective echo-enhancers in present-day clinical practice will open up new oppurtunities

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F Calliada, R Campani, O Bottinelli, A Bozzini, M G Sommaruga. 1998. Ultrasound contrast agents: basic principles.. https://doi.org/10.1016/s0720-048x(98)00057-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Lysophosphatidic acid (LPA) receptors are activated differentially by biological fluids: possible role of LPA-binding proteins in activation of LPA receptors.

Lysophosphatidic acid (LPA) exerts multiple biological functions through G protein-coupled receptors (EDG2/LPA(1), EDG4/LPA(2), and EDG7/LPA(3)) and is present in serum where it is associated with albumin. In this study we examined LPA activity in various biological fluids by measuring the LPA-induced increase in the intracellular concentration of calcium ion in three types of Sf9 insect cells, each expressing one of the LPA receptors. Using this system, we found that EDG2 and EDG4, but not EDG7, were activated strongly by addition of incubated plasma. By contrast, LPA detected in seminal plasma, which contains a low concentration of albumin, selectively activated EDG7. After LPA in these samples was extracted and reconstituted, it activated all three receptors. We also found that serum albumin readily inhibits the activation of EDG7 but not the activation of EDG2 or EDG4. In addition, plasma from Nagase analbuminemic rats but not plasma from control Sprague-Dawley rats was found to strongly activate EDG7, although the plasma of these two types of rats contained equal amounts of LPA and activated both EDG2 and EDG4. The present study shows that serum albumin can negatively regulate EDG7 but not EDG2 or EDG4, and suggests that protein factors are present in seminal plasma and deliver LPA efficiently to EDG7 but not to EDG2 or EDG4.

Albumins↗

Metabolic pre-conditioning of cultured cells in physiological levels of insulin: generating resistance to the lipid-accumulating effects of plasma in hepatocytes.

Understanding the regulation of hepatocyte lipid metabolism is important for several biotechnological applications involving liver cells. During exposure of hepatocytes to plasma, as is the case in extracorporeal bioartificial liver assist devices, it has been reported that hepatic-specific functions, e.g., albumin and urea synthesis and diazepam removal, are dramatically compromised and hepatocytes progressively accumulate cytoplasmic lipid droplets. We hypothesized that the composition of hepatocyte culture medium significantly affects lipid metabolism during subsequent plasma exposure. Rat hepatocytes were cultured in medium containing either physiological (50 microU/mL) or supra-physiological (500 mU/mL) insulin levels for 1 week and then exposed to human plasma supplemented with or without amino acids. We found that insulin's anabolic effects, such as stimulation of triglyceride storage, were carried over from the pre-conditioning to the plasma exposure period. While hepatocytes cultured in high insulin medium accumulated large quantities of triglycerides during subsequent plasma exposure, culture in low insulin medium largely prevented lipid accumulation. Urea and albumin secretion, as well as the ammonia removal rate, were largely unaffected by insulin but increased with amino acid supplementation. Thus, hepatocyte metabolism during plasma exposure can be modulated by medium pre-conditioning and supplements added to plasma.

Albumins↗