PubMed Health⌕ Search

PubMed · 9666976

Perceived head-centric speed is affected by both extra-retinal and retinal errors.

Abstract

When we make a smooth eye movement to track a moving object, the visual system must take the eye's movement into account in order to estimate the object's velocity relative to the head. This can be done by using extra-retinal signals to estimate eye velocity and then subtracting expected from observed retinal motion. Two familiar illusions of perceived velocity--the Filehne illusion and Aubert-Fleischl phenomenon--are thought to be the consequence of the extra-retinal signal underestimating eye velocity. These explanations assume that retinal motion is encoded accurately, which is questionable because perceived retinal speed is strongly affected by several stimulus properties. We develop and test a model of head-centric velocity perception that incorporates errors in estimating eye velocity and in retinal-motion sensing. The model predicts that the magnitude and direction of the Filehne illusion and Aubert-Fleischl phenomenon depend on spatial frequency and this prediction is confirmed experimentally.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T C Freeman, M S Banks. 1998. Perceived head-centric speed is affected by both extra-retinal and retinal errors.. https://doi.org/10.1016/s0042-6989(97)00395-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Multidetector CT and dentascan software: dosimetric evaluation and technique improvement.

PURPOSE: The development of new operative techniques in oral and maxillofacial surgery within the last few years has led to an increasing demand for Dentascan examination, also in paediatric patients. It is necessary to modify acquisition parameters to reduce the absorbed dose. The aim of this study was to define a Dentascan protocol in which a reduced X-ray dose could be used. MATERIALS AND METHODS: Dosimeters were applied to the eyes, mouth, parotid glands, thyroid and back of the neck of an anthropomorphic Plexiglas phantom that underwent multidetector computed tomography (MDCT) Dentascan examinations. Both 120kV and 80 kV were used to study the mandibular and maxillary arches. RESULTS: Examinations obtained with the 80 kV protocol showed a ten-fold reduction in the absorbed dose, without affecting image quality. CONCLUSIONS: We suggest a Dentascan protocol that reduces the X-ray dose administered to the patient while ensuring the same high diagnostic accuracy.

Head↗