[Partial liquid ventilation].

Abstract

Partial liquid ventilation (PLV) is a relatively new therapeutic approach to acute lung injury (ALI) and the acute respiratory distress syndrome (ARDS). The idea of combining the intrapulmonary application of an oxygen-carrying substance and positive pressure ventilation was introduced by Fuhrman in 1991 and originally called perfluorocarbon-associated gas exchange (PAGE). Nowadays, the technique is mostly known as partial liquid ventilation (PLV). The efficacy of PVL treatment has been demonstrated in numerous animal studies in different models of lung injury. The results of those studies led to multicenter phase I-II studies in patients of all age groups in the United States and Canada. Recently, the first randomized, controlled study in 90 adult patients suffering from ALI and ARDS was completed and first results have been published. Comparison of overall mortality and number of ventilator-free days (VFD's) in a 28-day period showed no differences between PLV and conventionally treated patients. A post-hoc stratification by age (< 55 years) demonstrated a tendency to lower mortality (PLV 25.6%; CMV 36.8%) and a significant increase of VFD (PLV 8.95 days; CMV 4.11 days; p = 0.03) in PLV when compared to conventionally treated patients. Perfluorocarbons (PFCs) are chemically stable and inert. They are mostly eliminated via exhalation (> 99%). The unique physicochemical properties of PFCs permit access to atelectatic, non-ventilated lung areas, enhance gas exchange and decrease inflammation. The dense PFCs prevent the endexpiratory collapse of alveoli and reestablish functional residual capacity (FRC). Comparable to positive endexpiratory pressure (PEEP), these effects have been described as "liquid or fluid PEEP". These properties offer a new approach to the underlying pathophysiology of ALI and ARDS. In addition, the combination with other therapeutic approaches to ALI and ARDS like high-frequency oscillations (HFO), inhaled nitric oxide (NO) therapy, and surfactant replacement can be considered and is already the subject of recent publications. However, combination therapy is still experimental and further investigation is necessary to evaluate efficacy and potential risks. Many questions still exist which need to be answered by experimental as well as human pilot studies. Based on these studies, the results of ongoing human trials can be assessed properly and new multicenter trials can be planned effectively.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Quintel, J Meinhardt, K F Waschke. 1998. [Partial liquid ventilation].. https://doi.org/10.1007/s001010050586

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

New technologies in the assessment of hemodynamic parameters.

Pulmonary artery catheter (PAC) use has led to major advances in the assessment of hemodynamics. Since its introduction three decades ago, features have been added to the PAC to enhance its hemodynamic monitoring capabilities. In addition, newer technologies have been proposed to replace the PAC. This article discusses three features that enhance the PAC--measures of mixed venous oxyhemoglobin, right ventricular ejection fraction, and continuous cardiac output--and two newer technologies--esophageal Doppler and exhaled carbon dioxide measurements. The article describes current and future applications of hemodynamic monitoring.

Blood Gas Analysis↗

Cardiac exercise hemodynamics late after partial left ventriculectomy.

BACKGROUND: Although some patients report favorable activity levels late after partial left ventriculectomy (PLV), their exercise physiology has not been well described. METHODS AND RESULTS: We performed upright bicycle hemodynamics in 10 patients (9 men) aged 56+/-12 years at 1.7 years after PLV. Ejection fraction was 25+/-4%. Patients biked 10+/-7 minutes. With exercise, the mean pulmonary arterial pressure rose from 36+/-12 to 52+/-10 mm Hg (P:=0.0003). The mean pulmonary capillary wedge pressure rose from 25+/-14 to 36+/-9 mm Hg (P:=0.0566), and the cardiac index rose from 2.2+/-0.5 to 3.8+/-1.6 L. min(-1). m(-2) (P:=0.0077). The mixed venous oxygenation with exercise declined from 44+/-9% to 24+/-17% (P:=0. 0220), and the pulmonary vascular resistance increased from 2.0+/-0. 9 to 2.3+/-1.1 Wood units (P:=0.5566). CONCLUSIONS: In late follow-up after PLV with exercise, the cardiac index is significantly augmented. However, there are further rises in pulmonary artery and pulmonary capillary wedge pressures, suggesting abnormal compliance, with marked decline in mixed venous oxygenation. Elucidating late physiology after PLV may help pave the way for future innovative heart failure surgeries.

Blood Gas Analysis↗