Diamond coated total hip replacements.

Abstract

Diamond has many superior, desired characteristics of implant materials such as low friction, high wear and corrosion resistance, and well bonding surface to bone. The potential of diamond for total hip replacement implants was studied in the form of amorphous diamond coatings on conventional metal implant materials. Amorphous diamond coatings (sp3 bonding fraction 80%, thickness 0.2 to 10 microns) were deposited on stainless steel AISI316L, Ti6A14V, and CoCrMo alloys using filtered pulsed plasma are discharge method. Superior attachment of coatings to the implant materials was achieved by using high energy plasma beams to deposit amorphous diamond and proper intermediate layers. Previously it was shown that these coatings are biocompatible causing no local tissue reactions. Tribologic studies using a pin on disk apparatus with coated or uncoated implant materials in 1 wt.% NaCl distilled water were performed. A simplified hip joint simulator was used for preliminary testing of metal on polyethylene and metal on metal artificial hip joints modified with amorphous diamond coating. The average coefficients of friction were typically in the range of 0.03 to 0.11 for amorphous diamond coated materials. In the case of metal on metal hip implants, the average friction during initial running in period was improved (coefficient of friction = 0.07) compared with the same metal on metal pair (coefficient of friction = 0.22) and sliding was significantly smoother. In pin on disk wear tests, the average wear factors obtained were 140.10(-6), 5.0.10(-6), and << 0.1.10(-6) mm3/Nm for the pairs of AISI316L, CoCrMo, and the same materials with amorphous diamond coating. The corrosion rates of these implant materials in 10 wt.% HCl solution were decreased by a factor of 10,000 to 15,000 and any damage of the coatings was not observed in 6 months. The results of the tests show that in all the combinations studied, amorphous diamond coating improved definitely the wear and corrosion resistance compared with the uncoated materials.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Lappalainen, A Anttila, H Heinonen. 1998. Diamond coated total hip replacements.. https://pubmed.ncbi.nlm.nih.gov/9678039/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Development of a 3D cell culture system for investigating cell interactions with electrospun fibers.

There are many variables to be considered in studying how cells interact with 3D scaffolds used in tissue engineering. In this study we investigated the influence of the fiber diameter and interfiber spaces of 3D electrospun fiber scaffolds on the behavior of human dermal fibroblasts. Fibers of two dissimilar model materials, polystyrene and poly-L-lactic acid, with a broad range of diameters were constructed in a specifically developed 3D cell culture system. When fibroblasts were introduced to freestanding fibers, and encouraged to "walk the plank," a minimum fiber diameter of 10 microm was observed for cell adhesion and migration, irrespective of fiber material chemistry. A distance between fibers of up to 200 microm was also observed to be the maximum gap that could be bridged by cell aggregates--a behavior not seen in conventional 2D culture. This approach has identified some basic micro-architectural parameters for electrospun scaffold design and some key differences in fibroblast growth in 3D. We suggest the findings will be of value for optimizing the integration of cells in these scaffolds for skin tissue engineering.

Biocompatible Materials↗

Improved catalytic properties of immobilized lipases by the presence of very low concentrations of detergents in the reaction medium.

The addition of a very small concentration of a detergent (in many instances under the critical micellar concentration (cmc)) has been found to greatly increase the activity of immobilized lipases, using those from Pseudomonas fluorescens (PFL) and Candida antarctica (isoform B) as model enzymes. However, the detergents may also have a negative effect on enzyme activity; in fact, for all enzyme preparations and substrates the activity/detergent concentration curve reached a maximum value and started to decrease, in many instances even under the initial value. The concentration and nature of the detergent (SDS, CTAB, Triton X-100, or X-45) that permitted the maximum hyperactivation was different depending on the substrate. The best hyperactivation values promoted by the presence of detergent were over a 20-fold factor. The presence of detergents permitted the inhibition of lipases by irreversible covalent inhibitors (e.g., 4-(2-aminoethyl)benzenesulfonyl fluoride hydrochloride) (AEBSF) while the enzyme, in the absence of detergent, is not inhibited by these irreversible inhibitors. This suggested that the main effect of the detergents is to shift the conformational equilibrium of lipases toward the open form. Moreover, the presence of detergents also permitted to improve the enantioselectivity exhibited by the immobilized lipases in some cases. For example, the enantioselectivity of PFL-glyoxyl agarose increased from 40 to more than 100 in the hydrolysis of (+/-)-2-hydroxy-4-phenylbutyric acid ethyl ester by using 0.1% CTAB.

Biocompatible Materials↗

Development of wollastonite-poly(ethylmethacrylate co-vinylpyrrolidone) based materials for multifunctional devices.

The manufacturing of a composite made of a synthetic bioactive ceramic, pseudowollastonite (psW), and a bioresorbable copolymer ethylmethacrylate-vinylpyrrolidone (EMA/VP) is presented in this article. psW porous blocks were produced by dipping an open porous polyurethane foam in a psW containing slurry. A 40/60 wt % EMA/VP monomers mixture was poured on the blocks, and free radical polymerization initiated by azobis(isobutyronitrile) at 50 degrees C. Disks of 1 mm height were obtained by cutting the composite with a diamond saw, and bioresorption and bioactivity of the specimens were tested by immersion of the disks into SBF. A ceramic/polymer weight ratio of 72/28, greater than the usually achievable ratio by polymeric solidification of slurries of monomers charged with a powdered solid component, has been obtained. The system is bioactive and does not change the pH of the medium during the degradation test.

Biocompatible Materials↗