PubMed Health⌕ Search

PubMed · 9690112

[Atrial defibrillator].

Abstract

Atrial fibrillation (AF) is a frequent and costly health care problem representing the most common arrhythmia resulting in hospital admission. Total mortality and cardiovascular mortality are significantly increased in patients with AF compared to controls. In addition to symptoms of palpitations patients with AF have an increased risk of stroke and may also develop decreased exercise tolerance and left ventricular dysfunction. All of these problems may be reversed with restoration and maintenance of sinus rhythm. External electrical cardioversion has been a remarkably effective and safe method for termination of this arrhythmia. Originally described by Lown et al. in 1963, it has been a well accepted mode of acute therapy. However, this technique requires general anesthesia or heavy sedation. Internal atrial defibrillation has been evaluated as an alternative approach to the external technique for over 2 decades. Recent studies have shown that low-energy internal atrial defibrillation using biphasic shocks is an effective and safe means in restoring sinus rhythm in patients with AF and should be considered especially in patients in whom external cardioversion attempts have failed. IMPLANTABLE ATRIAL DEFIBRILLATOR: Recently, a stand alone IAD, the Metrix System (model 3000 and 3020), has entered clinical investigation. Atrial defibrillation is accomplished by a shock delivered between electrodes in the right atrium and the coronary sinus. The right atrium lead has an active fixation in the right atrium. The coronary sinus lead has a natural spiral configuration for retention in the coronary sinus, and can be straightened with a stylet. Both leads are 7 French in diameter and the defibrillation coils are each 6 cm in length. The electrodes may be placed using separate leads, or very soon by using a single bipolar lead. A separate bipolar right ventricular lead is used for R wave synchronization and post shock pacing. The Metrix defibrillator can be used to induce AF by using R wave synchronous shocks and can store intracardiac electrograms (EGMs) for up to 2 minutes from the most recent 6 AF episodes. The device can be programmed into one of the following operating modes: fully automatic, patient activated, monitor mode, bradycardia pacing only, and off. As AF is not life-threatening, in the automatic mode the device is only intermittently active in detecting and treating AF, and this "sleep wake-up" cycle interval is programmable. The device employs extensive processing both for detection and R wave synchronization. In April 1996, the phase I Metrix multicenter clinical trial was started. As of May 1997, a total of 51 Metrix systems had been implanted as part of the phase I multicenter clinical trial. Preliminary data suggest that both defibrillation thresholds and electrograms are stable over time (implant to 3 months). Detection accuracy has been excellent (100% specificity, 92.3% sensitivity) and there have been no errors of R wave selection for synchronization. No proarrhythmias have resulted from over 3700 shocks delivered. The device is effective in electrically converting 96% of the spontaneous episodes of AF. In 27% of episodes several shocks were required because of early recurrence of AF. In 5 patients, the atrial defibrillator was removed: 2 infections, 1 cardiac tamponade, 1 permanent loss of telemetry, 1 patient required His-Bundle ablation because of frequent episodes of drug refractory AF with rapid ventricular response. Initial clinical experience under controlled conditions with the Metrix system suggests that the implantable atrial defibrillator may offer a therapeutic alternative for a subgroup of patients with drug refractory, symptomatic, long lasting, and infrequent episodes of AF. Further efforts must be undertaken to reduce the patient discomfort associated with internal atrial defibrillation in an attempt to make this new therapy acceptable to a larger patient population with AF. (ABSTRACT TRUNCATED)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W Jung, B Lüderitz. 1998. [Atrial defibrillator].. https://doi.org/10.1007/bf03044320

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

RR-interval-based atrial fibrillation detection and burden estimation: cross-dataset validation and calibration-aware probability analysis.

Objective.Atrial fibrillation (AF) burden has become an increasingly important endpoint in long-duration rhythm monitoring, but reliable burden estimation requires more than accurate AF detection alone. In particular, when burden is derived by aggregating predicted AF probabilities over time, probability calibration may directly affect burden validity under external dataset shift.Approach.This study developed an interpretable-interval feature model for AF detection and evaluated it using record-wise cross-validation on a development cohort and independent cross-dataset external validation on public Holter electrocardiographic databases. Window-level performance was assessed using the area under the receiver operating characteristic curve (ROC-AUC), area under the precision-recall curve (PR-AUC), Brier score, expected calibration error (ECE), and calibration intercept and calibration slope. Recording-level AF burden was estimated using both probability-based and hard-label aggregation and evaluated using mean absolute error (MAE) and agreement analyses.Main results.The model showed high discrimination in both development and external evaluation, with external ROC-AUC ofand PR-AUC of. However, external calibration deteriorated despite preserved ranking performance, with Brier score of, ECE(15) of, calibration intercept of, and calibration slope of. In the external cohort, probability-based burden estimation preserved strong association with reference burden but showed weaker raw agreement than hard-label aggregation, with MAE ofversus, consistent with systematic probability underprediction. Repeated external recalibration across record-level splits substantially improved probability quality and probability-based burden estimation. Median probability-burden MAE decreased fromwithout recalibration toafter Platt recalibration andafter isotonic recalibration, while median ECE(15) decreased fromtoand, respectively.Significance.These findings indicate that-interval-based AF detection maintained strong ranking performance in the tested external cohort, but probability calibration should be evaluated explicitly when predicted probabilities are aggregated into AF-burden estimates.

Atrial Fibrillation↗

Research on identification of key genes and immune-metabolic mechanisms in atrial fibrillation through integrated multi-cohort transcriptomic analysis and machine learning.

This study aimed to integrate multiple datasets for the identification of atrial fibrillation (AF)-related differentially expressed genes (DEGs), analyze their underlying mechanisms through functional enrichment and machine learning, construct diagnostic models, and explore immune-metabolic interactions to provide novel biomarkers and theoretical foundations. Gene expression datasets were integrated and normalized, with batch effects removed using principal component analysis. Differential expression analysis, functional enrichment analysis (Gene Ontology and Kyoto Encyclopedia of Genes and Genomes pathways), and machine learning-based feature gene selection and model construction were performed. Shapley additive explanations analysis was utilized to interpret the constructed models, while gene set enrichment analysis, gene set variation analysis, and immune cell infiltration analysis were conducted to investigate the associations between feature genes and immune infiltration. After integrating and normalizing gene expression data and eliminating batch effects via principal component analysis, 6 DEGs were identified, including 4 upregulated and 2 down-regulated ones. Functional enrichment analysis showed these DEGs were significantly enriched in neuro-related biological processes and pathways, indicating their key roles in AF pathogenesis. Five key feature genes were selected using LASSO, random forest, and support vector machine-recursive feature elimination algorithms. They had significant expression differences between the AF and control groups (P&#x2005;<&#x2005;.001) and were located on distinct chromosomes. The constructed random forest and support vector machine models performed excellently (area under the curve&#x2005;&#x2265;&#x2005;0.85). Shapley additive explanations analysis revealed TNNI1 contributed most to model prediction, with its expression significantly positively correlated with immune cell infiltration. Gene set enrichment analysis and gene set variation analysis analyses further showed feature genes participated in AF pathogenesis by regulating immune modulation, metabolic pathways, and autophagy. Immune cell infiltration analysis found altered proportions of T-cell subsets and M0 macrophages in the AF group, along with complex links between feature gene expression and immune cell function. This study systematically elucidated the unique gene expression patterns and key regulatory pathways associated with AF, clarifying the crucial roles of feature genes in immune regulation, metabolic imbalance, and cellular dysfunction. These findings provide a theoretical basis and potential therapeutic targets for understanding AF pathogenesis and developing targeted treatment strategies.

Atrial Fibrillation↗

Horse model of spontaneous atrial fibrillation share proteomic changes with humans.

Horses and humans are among the few mammals susceptible to spontaneous atrial fibrillation (AF), both suffering from high recurrence rates after treatment. Treatment resistance is often attributed to progressive atrial remodeling, but current treatment options fail to effectively address this aspect. Here, we introduce a novel horse model of spontaneous AF to investigate the biological pathway changes in early stages of the disease. Through data-independent acquisition mass spectrometry on biopsies from the right and left atrium and left ventricular chamber of horses with early-stage persistent AF (n&#x2009;=&#x2009;8) and controls (n&#x2009;=&#x2009;8), we identify several differentially regulated proteins across all three chambers. Pathway enrichment analyses and histological stainings highlight a significant role of atrial extracellular matrix (ECM) remodeling in early AF. Other key proteomic changes relate to metabolism, contractility, and protein-folding, and overlap with findings from publicly available human datasets. Our results demonstrate that horses and humans share several AF-related proteomic changes, providing translational insights into the early atrial remodeling processes that are likely to contribute to treatment resistance. These protein-level changes could serve as biomarkers or pharmacological targets for preventing AF-associated atrial remodeling and improve treatment outcomes across species.

Atrial Fibrillation↗