PubMed Health⌕ Search

PubMed · 9699406

Frictional forces related to self-ligating brackets.

Abstract

Orthodontic tooth movement can be regarded as teeth sliding on a wire like pearls on a string, the force being supplied by springs or elastics. The movement implies friction between wire and bracket, taking up part of the force and leaving an uncontrolled amount to act on the teeth. The friction is likely to depend on bracket construction and wire material. Therefore, in this investigation the friction of self-ligating brackets and beta-titanium wires was evaluated, as opposed to more conventional configurations. Carried by low-friction linear ball bearings, a bracket was made to slide along an out-stretched archwire with minimal (and known) basic friction, either parallel or at an angle to the wire. Two self-ligating brackets were used in their closed position without any normal force. Friction was tested against four wires: stainless steel and beta-titanium, both in round and rectangular cross-sections. The force used to overcome friction and to move the bracket was measured on a testing machine at 10 mm/min, and the basic friction was subtracted. The results show that round wires had a lower friction than rectangular wires, the beta-titanium wires had a markedly higher friction than stainless steel wires, and friction increased with angulation for all bracket/wire combinations. The self-ligating brackets had a markedly lower friction than conventional brackets at all angulations, and self-ligating brackets, closed by the capping of a conventional design, exhibited a significantly lower friction than self-ligating brackets closed by a spring. The selection of bracket design, wire material, and wire cross-section significantly influences the forces acting in a continuous arch system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Pizzoni, G Ravnholt, B Melsen. 1998. Frictional forces related to self-ligating brackets.. https://doi.org/10.1093/ejo%2F20.3.283

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A user-friendly PC-based data acquisition and analysis system for respirometric investigations.

We have developed an easy-to-use computer-based system for recording, displaying, storing and analyzing signals generated by Clark-type oxygen electrodes. A user-friendly interface of Windows-based program BioMed significantly increases the productivity of investigations. It allows to process, control, present and archive the experimental data in real time. A 12-bit analog-to-digital-converter, analog and digital filters, a possibility to zoom the obtained respiratory curves and calculation of the respiration rates by a linear regression method increase the resolution of the estimated oxygen consumption rates. The new system enables to register even small changes, such as 3-5 ngatoms O/min, in respiration rates of biological objects -- enzymes, mitochondria and permeabilized muscle fibers. The system has been developed and is regularly used for the respirometric investigations at the Laboratory of Biochemistry, Institute for Biomedical Research, Kaunas University of Medicine.

Analog-Digital Conversion↗

Elimination of depth degeneracy in optical frequency-domain imaging through polarization-based optical demodulation.

A novel optical frequency-domain imaging system is demonstrated that employs a passive optical demodulation circuit and a chirped digital acquisition clock derived from a voltage-controlled oscillator. The demodulation circuit allows the separation of signals from positive and negative depths to better than 50 dB, thereby eliminating depth degeneracy and doubling the imaging depth range. Our system design is compatible with dual-balanced and polarization-diverse detection, important techniques in the practical biomedical application of optical frequency-domain imaging.

Analog-Digital Conversion↗