PubMed HealthSearch

PubMed · 9715005

Toothbrush care.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R T Glass. 1998. Toothbrush care.. https://doi.org/10.14219/jada.archive.1998.0363

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A new way of removing silicone oil from the surface of silicone intraocular lenses.

PURPOSE: This study was performed to ascertain the efficacy of Perfluorhexyl-octan, C14F13H17 (F6H8), in dissolving silicone oil from the surface of silicone intraocular lenses. So far F6H8 is the only solvent of silicone oil that is tolerated by intraocular tissues. MATERIALS AND METHODS: Intraocular silicone lenses (Domilens) were examined after application of small droplets of silicone oil of two different viscosities (AdatoSIL-OL 1000 and 5000) followed by rinsing with F6H8. To allow distinction between silicone oil and F6H8 the silicone oil was stained. Microscopic examination was carried out under video control. RESULTS: One hundred microliters of AdatoSIL-OL 1000 could be easily removed with about 800 microl of F6H8; 50 microl of AdatoSIL-OL 5000 also disappeared after 800 microl of F6H8. A larger drop of the latter oil could not be removed even after application of 2 ml of F6H8. CONCLUSION: Silicone oil 1000 can be easily dissolved by F6H8, whereas silicone oil 5000 is more difficult to remove because of its higher viscosity.

Equipment Contamination

Sporicidal activity of a new low-temperature sterilization technology: the Sterrad 50 sterilizer.

This study was undertaken to evaluate the efficacy of a new low-temperature sterilization system that recently has been cleared by the Food and Drug Administration, the Sterrad 50. Flat stainless steel carriers were inoculated with approximately 10(6) Bacillus stearothermophilus spores. These carriers were placed aseptically in the middle of 40-cm-long stainless steel-lumened test units of varying diameters (1 mm, 2 mm, and 3 mm). After inoculation, the test units were processed in the Sterrad 50. After sterilization, the carriers were assayed for growth of the B. stearothermophilus spores. Our data demonstrated that the Sterrad 50 was highly effective in killing the B. stearothermophilus spores (no positive carriers with 30 tests of each lumen-diameter test unit). The Sterrad 50 is likely to be clinically useful for the sterilization of heat-sensitive medical equipment.

Equipment Contamination

The monitoring of contaminated impervious planar surfaces.

The responses of several types of surface contamination monitor have been investigated for three typical working surfaces contaminated by three radionuclides commonly used in diagnostic or analytical biomedical applications. Of the three radionuclides, 99mTc is an intermediate-energy gamma emitter, 125I decays by electron capture, emitting low-energy x-rays, and 32P is a moderate-energy beta emitter. For each radionuclide monitored values have generally been found to be within 30% of projected response, this being based on calibrations which make use of standard radionuclide sources and conditions. The several types of contaminated non-absorbent surface that have been investigated produce monitored values which for a given type of monitor and radionuclide cannot be differentiated from each other.

Equipment Contamination