PubMed · 9730768
Standardized echography, pattern electroretinography and visual-evoked potential and automated perimetry in the early diagnosis of Graves' neuropathy.
Abstract
Twenty-four patients (47 eyes) affected by Graves' disease were enrolled to evaluate the role of standardized echography, pattern electroretinogram (P-ERG), visual evoked potentials (P-VEPs) and automated perimetry in the early diagnosis of the compressive optic neuropathy (CON). The P-ERG amplitude reduction was the most sensitive parameter to demonstrate an early impairment of the optic nerve (ON) function. We found a significant negative correlation between the ON diameter and the P-ERG amplitude. VEPs responses were also altered, but their ability in detecting an early ON damage was less sensitive and specific than P-ERG. The visual field damage was often aspecific and delayed with respect to electrophysiological alterations.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
F Genovesi-Ebert, E Di Bartolo, A Lepri, V Poggi, A Romani, M Nardi. 1998. Standardized echography, pattern electroretinography and visual-evoked potential and automated perimetry in the early diagnosis of Graves' neuropathy.. https://doi.org/10.1159/000055442
Cite the original work for its findings. Save a collection to share your selection of sources.