A collaborative study of infant respiratory function testing.

Abstract

The aims of this study were to compare inter-observer variability within and between two specialized infant lung function testing centres and to develop a strategy for performing and analysing infant respiratory function tests to facilitate future collaborative trials. A protocol for data collection and analysis was developed using similar equipment and identical software. All raw data were exchanged on disk and analysed, blind to infant status. All data were cross-analysed by both centres to assess inter-observer variability. Outcome measures were functional residual capacity (FRCpleth), airway resistance (Raw) and maximal expiratory flow at FRC (V'max,FRC). Subjects were recruited from the multicentre UK extracorporeal membrane oxygenation (ECMO) Trial and measured at around 1 yr of age. Forty-two infants attended the Institute of Child Health, London and 36 attended the Leicester Royal Infirmary. The proportion of infants treated with ECMO or conventional management at each centre was similar. There were no significant differences between any of the outcome measures for infants tested at either centre. During a cross-analysis, the agreement between the two centres, within infant, was closer for V'max,FRC and FRCpleth (within 10%) than for the more variable measurements of Raw (within 20%). A collaborative approach to trials with infant respiratory function as an outcome measure appears feasible, providing that close attention is paid to study design, and participants in such trials maintain a standard approach to data collection and analysis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

I Dundas, C Beardsmore, T Wellman, J Stocks. 1998. A collaborative study of infant respiratory function testing.. https://doi.org/10.1183/09031936.98.12040944

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Pre/postbronchodilator interrupter resistance values in healthy young children.

The interrupter technique estimates flow resistance. It entails occlusion of the airways during tidal breathing while flow and mouth pressure are recorded. This noninvasive technique is easy to use in young children. The aim of the present study was to measure inspiratory and expiratory interrupter resistance (Rint(insp), Rint(exp)) before and after bronchodilator administration in young healthy white children. We designed a multicenter study using a standardized procedure for Rint measurements. Centers in five French cities studied 91 children (48 boys and 43 girls; height, 92 to 129 cm; mean age 5.3 +/- 1.4 years). Mean values were not significantly different for Rint(insp) and Rint(exp) (0.78 +/- 0.21 versus 0.78 +/- 0.20 KPa x L(-1) x second). However, the difference between Rint(insp) and Rint(exp) decreased significantly with age and being positive before 5 years and negative later on (p < 0.02). Rint(insp) and Rint(exp) decreased significantly with height (Rint(insp) [KPa x L(-1) x second] = 2.289 - 1.37. 10(-2) x H [cm], Rint(exp) [KPa. L(-1) x second] = 2.021 - 1.12.10(-2) x H [cm]; p < 0.001). Bronchodilator (salbutamol) administration significantly decreased Rint(insp) and Rint(exp) (p < 0.001). Bronchodilator-induced changes (% of predicted values) in mean Rint(insp) and mean Rint(exp) were -15% (95% confidence interval, -46 to +15%) and -12% (95% confidence interval, -46 to +22%), respectively. Sex did not affect pre- or postbronchodilator values. Data from the present study may prove useful for testing lung function in young children with respiratory disorders who failed to cooperate with forced expiratory maneuvers.

Airway Resistance↗

Diagnosis of sleep apnea by automatic analysis of nasal pressure and forced oscillation impedance.

Detecting and differentiating central and obstructive respiratory events is an important aspect of the diagnosis of sleep-related breathing disorders with respect to the choice of an appropriate treatment. The purpose of this study was to evaluate the performance of a new algorithm for automated detection and classification of apneas and hypopneas, compared with visual analysis of standard polysomnographic signals. The algorithm is based on time series analysis of nasal mask pressure and a forced oscillation signal related to mechanical respiratory input impedance, measured at a frequency of 20 Hz throughout the night. The method was applied to all-night measurements on 19 subjects. Two experts in sleep medicine independently scored the corresponding simultaneously recorded polysomnographic signals. Evaluating the agreement between two scorers by a weighted kappa statistic on a second-by-second basis, we found that inter-expert variability and the discrepancy between automatic analysis and visual analysis performed by an expert were not significantly different. Implementation of this algorithm in a device for home monitoring of breathing during sleep might aid in the differential diagnosis of sleep-related breathing disorders and/or as a means for follow-up and treatment control.

Airway Resistance↗

Airway pressures and early barotrauma in patients with acute lung injury and acute respiratory distress syndrome.

The determinants of barotrauma in mechanically ventilated patients with acute lung injury or acute respiratory distress syndrome (ALI/ARDS) have not been clearly established. Using data from ARDS Network randomized controlled trials, we retrospectively examined the association between airway pressures and the risk of early barotrauma in a cohort of 718 patients with ALI/ARDS and no baseline barotrauma. We studied airway pressures at three exposure intervals: baseline, one day preceding the barotrauma event (one-day lag), and concurrent with the barotrauma event. During the first four study days, the cumulative incidence of barotrauma was 13% (95% confidence interval [CI] 10.6 to 15.6%). In a forward stepwise Cox proportional hazards analysis using time-dependent variables, higher concurrent positive end-expiratory pressure (PEEP) was associated with an increased risk of early barotrauma (relative hazard [RH] 1.67 per 5-cm H2O increment; 95% CI 1.35-2.07). Once concurrent PEEP was selected into the model, no other airway pressure was related to barotrauma, including plateau pressure. In the multivariate analysis, higher concurrent PEEP was also related to a greater risk of barotrauma (RH 1.93; 95% CI 1.44-2.60), controlling for age, ventilator group (6 versus 12 ml/kg), baseline PEEP, baseline plateau pressure, baseline tidal volume, Acute Physiology and Chronic Health Evaluation score, vasopressor use, serum albumin, hepatic failure, and coagulopathy. When one-day lagged values of PEEP were analyzed, higher PEEP was associated with a greater risk of barotrauma (RH 1.38 per 5-cm H2O increment; 95% CI 1.09-1.76). Controlling for the covariates, higher PEEP was related to an increased risk of barotrauma (RH 1.50; 95% CI 0.98- 2.30). In conclusion, higher PEEP may increase the likelihood of early barotrauma in ALI/ARDS.

Airway Resistance↗