Viscoelastic-injecting cystotome.

Abstract

This continuous curvilinear capsulorhexis (CCC) technique is for use in complicated surgical cases such as when the anterior chamber is shallow, the red reflex is not good, or eye movements are present. This technique is easier and safer in such cases because it uses a cystotome connected to a viscoelastic syringe. First, the anterior chamber is filled with viscoelastic material using a conventional cannula. The cannula is replaced with a bent needle (or cystotome), and the CCC is performed in the usual way. This instrument allows the surgeon to inject small amounts of viscoelastic material exactly where and when it is needed. The anterior chamber remains deep while the CCC is performed, and the anterior capsule tear is done in a more controlled fashion.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M A Teus, M A Fagúndez-Vargas, M A Calvo, A Marcos. 1998. Viscoelastic-injecting cystotome.. https://doi.org/10.1016/s0886-3350(98)80162-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Model of pulsatile-flow of aqueous humor through the iris-lens canal.

PURPOSE: To present a model of pulsatile-flow of aqueous humor from posterior (PC) to anterior chamber (AC) and to analyze the sensitivity of this novel model in detecting typical high risk conditions predisposing to pupillary block. METHODS: The model assumes noncontinuous flow of aqueous through the iris-lens canal. Aqueous that fills the canal will be ejected toward the AC-side of the canal at certain time intervals, and between 2 events of aqueous ejection there is no actual flow through this canal. Pupillary pumping rate (PPR) was calculated from the aqueous flow rate and the calculated volume of iris-lens canal. RESULTS: PPR values were generated by incorporating pupillary diameter (1 to 8 mm), aqueous flow rate (1 to 2.5 microL/min), and iris-lens canal width (0.5 to 2 mm) and height (3-9 microm) in numerical experimentation with the present model. PPR showed inverse dependence on iris-lens canal height and pupillary diameter and was directly proportional to aqueous flow rate, in agreement with the steady-flow model. However, contrary to the steady-flow model, PPR showed inverse dependence on iris-lens canal width and predicted the anticipated PC-AC pressure gradient changes at simulated light-dark transition in eyes of patients with clinically narrow angles and ultrasound biomicroscopy evidenced pupillary block. CONCLUSIONS: Upon the incorporation of real ultrasound biomicroscopy measurements in numerical experimentations with both models, the present pulsatile-flow model, contrary to the steady-flow model, showed good predictability of PC-AC pressure gradient changes in a typical condition predisposing to pupillary block.

Anterior Chamber↗