PubMed · 9831095

Transcutaneous optical telemetry system with infrared laser diode.

Abstract

A transcutaneous telemetry system is indispensable when monitoring and controlling the operation of an artificial heart totally implanted inside the body. A telemetry system using light is more useful than radio waves from the viewpoint of electromagnetic interference and power consumption. In this report, a transcutaneous optical coupler consisting of an infrared laser diode (LD) and a PIN photodiode (PINPD) was evaluated, and the transcutaneous optical coupling and information transmission characteristics were evaluated in in vitro experiments. The wavelength and directional angle of the LD used were 830 nm and 9.5 degrees, respectively. With regard to the directional angle of PINPD, the authors found that a PINPD with a larger directional angle allowed for more deviation between the axes optical axes of the LD and the PINPD. It was also found that the transcutaneous coupler had an optimum distance for the permissible deviation to be maximized. The information signals modulated by the phase shift keying (PSK) were transmitted at a rate of 9,600 bps through goat skin 4 mm thick, and demodulated by the phase locked loop (PLL) on the receiving side. As a result, the information signals were demodulated without any errors in deviation within 10.5 mm at a distance of 11 mm. In conclusion, the transcutaneous optical telemetry system using an infrared LD has sufficient characteristics to monitor and control the operation of an artificial heart totally implanted inside the body.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Inoue, K Shiba, E Shu, K Koshiji, K Tsukahara, T Oh-umi, T Masuzawa, E Tatsumi, Y Taenaka, H Takano. Transcutaneous optical telemetry system with infrared laser diode.. https://doi.org/10.1097/00002480-199811000-00014

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

On the closing sounds of a mechanical heart valve.

In the 1994 Replacement Heart Valve Guidance of the U.S. Food and Drug Administration (FDA), in-vitro testing is required to evaluate the potential for cavitation damage of a mechanical heart valve (MHV). To fulfill this requirement, the stroboscopic high-speed imaging method is commonly used to visualize cavitation bubbles at the instant of valve closure. The procedure is expensive; it is also limited because not every cavitation event is detected, thus leaving the possibility of missing the whole cavitation process. As an alternative, some researchers have suggested an acoustic cavitation-detection method, based on the observation that cavitation noise has a broadband spectrum. In practice, however, it is difficult to differentiate between cavitation noise and the valve closing sound, which may also contain high-frequency components. In the present study, the frequency characteristics of the closing sound in air of a Björk-Shiley Convexo-Concave (BSCC) valve are investigated. The occluder closing speed is used as a control parameter, which is measured via a laser sweeping technique. It is found that for the BSCC valve tested, the distribution of the sound energy over its frequency domain changes at different valve closing speeds, but the cut-off frequency remains unchanged at 123.32 +/- 6.12 kHz. The resonant frequencies of the occluder are also identified from the valve closing sound.

Heart, Artificial↗