PubMed Health⌕ Search

PubMed · 9852918

Autopsies in acute type A aortic dissection. Surgical implications.

Abstract

BACKGROUND: This study was undertaken to review autopsy findings in operative and nonoperative settings to define anatomic pathology, cause of death, and theoretical implications of operative and perfusion management strategies for acute Stanford type A dissection. METHODS AND RESULTS: Fifty autopsies for acute type A dissection performed between 1977 and 1995 were reviewed. Twenty-nine patients had no operative therapy (group A). Twenty-one patients received an operation (group B). Cause of death in the nonoperated group was tamponade or rupture in 23 patients (23 of 29, 79%). In the operated group, 1 patient died of rupture (1 of 21, 5%). The 2 most common causes of death in the operated group were major brain injury (7 of 21, 33%) and cardiac failure (7 of 21, 33%). Intimal disruption was present in 92% of patients (45 of 49). Twenty-four percent of these (12 of 49) had a secondary intimal injury site. Theoretic femoral arterial perfusion and application of an ascending aortic cross clamp would have left 42% of patients (21 of 50) at risk of false lumen perfusion against the aortic cross clamp. Replacement of the ascending aorta alone would have left residual arch intimal disruption in 32% of patients (16 of 50). Open arch inspection and repair when appropriate would have left a minimum number of patients with distal intimal disruption (8 of 50, 16%). CONCLUSIONS: Operative therapy successfully manages the primary cause of death in acute type A dissection. A theoretical repair that uses the open arch technique followed by antegrade perfusion eliminates or minimizes the risk of false lumen perfusion in the greatest number of patients. This technique may diminish neurological injury and distal anastomosis bleeding, thereby improving outcomes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G S Van Arsdell, T E David, J Butany. 1998-11-10. Autopsies in acute type A aortic dissection. Surgical implications.. https://pubmed.ncbi.nlm.nih.gov/9852918/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗