High-resolution cardiac imaging using an interleaved 3D double slab technique.

Abstract

A three-dimensional (3D) gradient-echo sequence with interleaved double-slab excitation was developed and optimized for the requirements in pediatric cardiac imaging. For this purpose high contrast between blood and myocardium signal should be obtained without the use of contrast agents. An acceptable measuring time for a large region examined with high spatial resolution should be achieved as well, especially with regard to the small structures of the heart and vessels of infants. The presented approach works with gradient moment nulling and a short echo time of 5.5 ms resulting in generally high signal intensity and only minor signal losses due to turbulent flow. The sequence allows simultaneous ECG-gated recording of two separately excited slabs with small thickness (10 mm) and with a distance of several centimeters between them. Thus, common effects of presaturation in 3D imaging can be avoided, although a relatively short measuring time is achievable. In order to get a 3D data set with good signal homogeneity of blood and of the other structures across a large volume of interest several double-slab measurements with suitable positions must be performed. The latter aspect is especially important for postprocessing techniques as multiple planar reconstruction and maximum intensity projection. Examples of applications of the new technique and appropriately postprocessed images are presented allowing demonstration even of subtle cardiac malformations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Forster, L Sieverding, J Breuer, F Schick, F Dammann, J Apitz, O Lutz. 1998. High-resolution cardiac imaging using an interleaved 3D double slab technique.. https://doi.org/10.1016/s0730-725x(98)00114-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗