A compact, flow-through centrifugation system has been developed specifically for high-throughput centrifugation of large numbers of samples. The instrument is based on multiple high-speed rotors that also serve as sample holders. The small size of the rotors allows them to be arrayed in a standard 96-well microtiter plate spacing, making this device ideal for highly parallel automated instrumentation. Though initially designed for cell separation in DNA sequencing protocols, the flow-through centrifuge can be used to replace conventional centrifugation in most processes involving small samples. Techniques for recovery of both the supernatant and the pellet have been developed, as well as techniques for sample mixing, and cleaning of the reusable rotors. This paper discusses the design and performance of the flow-through centrifuge applied to cell separation and resuspension and to DNA purification and concentration.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Marziali, T D Willis, R W Davis. 1999-01-05. An arrayable flow-through microcentrifuge for high-throughput instrumentation.. https://doi.org/10.1073/pnas.96.1.61

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Influence of flow patterns on chromatographic efficiency in centrifugal partition chromatography.

Visualization of flow patterns in centrifugal partition chromatography (CPC) was performed with an asynchronous camera and a stroboscope triggered by the CPC rotor, allowing a channel to be selected and observed regardless of rotational speed. Three main types of flow states were noted as a function of rotational speed and flow-rate: jets stuck along channel walls, broken jets and atomization. Our observations emphasize the importance of Coriolis force on flow shape. Chromatographic efficiency was related to the dispersion of the mobile phase in the stationary phase.

Centrifugation

Improvement purification of sulfated oligofucan by ion-exchange displacement centrifugal partition chromatography.

Centrifugal partition chromatography in ion-exchange displacement mode was used to fractionate mixtures of sulfated oligofucans obtained by partial depolymerization of brown seaweed fucoidans. Diluted (10%, v/v) protonated LA2 (a lipophilic secondary amine) is used as a weak exchanger. In an attempt to improve this method, several solvents (methyl isobutyl ketone, methyl tert.-butyl ether, BuOH) were tested to dissolve LA2H+. MtBE produced less bleeding than MiBK, whereas BuOH proved unsuitable. The sample injected needs to be highly diluted in water to ensure participation in the chromatographic process. A comparison of data (NMR, composition, molecular mass) indicated the homogeneity of the fractions obtained as well as the differences between them.

Centrifugation

Liquid-based cervical-cell collection with brushes and wooden spatulas: a comparison of 100 conventional smears from high-risk women to liquid-fixed cytocentrifuge slides, demonstrating a cost-effective, alternative monolayer slide preparation method.

Our purpose was to demonstrate that 17.5-mm liquid-based cytocentrifuge circle-slides made using a Hettich (Andreas Hettich Co., Tuttlingen, Germany) cytocentrifuge are at least as efficacious as conventional smears for detecting cervical abnormalities. One hundred conventional smears were collected with cytobrushes and wooden spatulas from high-risk women. Both devices were then placed into CytoRich Red (AutoCyte, Inc., Burlington, NC). Cells were concentrated from CytoRich Red by centrifugation and suspended in CytoRich Yellow. Two 17.5-mm circle-slides were produced, compared to each other in order to test reproducibility of diagnoses between slides, and compared to conventional slides. Sixty-five normals, three ASCUS, three LSIL, and two HSIL matched. Overall, cytocentrifugation yielded 27 additional findings among 25 cases. Also, it downgraded one conventional ASCUS to normal (immature metaplasia and chronic inflammation) and one conventional HSIL to normal (transitional cell metaplasia). Cytocentrifugation of 14 conventional normals afforded four ASCUS and 10 LSIL. Cytocentrifugation of 11 conventional ASCUS afforded nine LSIL and two HSIL (one with AIS). One HSIL + AIS was found with a conventional HSIL. Cytobrushes and wooden spatulas can be used to collect material for liquid-based cervico-vaginal cytology if they are placed into CytoRich Red. Hettich cytocentrifuge slides were more reliable than conventional smears in presenting well-dispersed, sharply imaged cells, affording greater diagnostic sensitivity and certainty. Compared to previous split-sample studies, three different outcomes were noted: 1) the endocervical component was consistently well-represented; 2) AIS was seen more often in liquid-based slides; and 3) the liquid-based slide did not underdiagnose its conventional companion. The liquid-based preparations downgraded one ASCUS to normal and one conventional HSIL to transitional-cell metaplasia. Histology correlation of these two cases agreed with the liquid-based cytology diagnoses, which validates their specificity. These improvements are ascribed to differences in fixation and processing. The low cost, ease of operation, and reusable chambers of the Hettich cytocentrifuge make it a cost-effective liquid-based cytology instrument, especially for small to intermediate-size laboratories. The claims that this paper makes must be proven by additional studies, and test implementation needs to be scrutinized by appropriate regulatory agencies whose standards may vary from country to country. Diagn. Cytopathol. 2000;22:86-91.

Centrifugation