PubMed Health⌕ Search

PubMed · 9883757

Pediatric circulatory support.

Abstract

BACKGROUND: Mechanical circulatory support in infants and small children is still a crucial issue. Until recently technological advances have been limited to the adult population. METHODS: Between February 1994 and December 1996, 553 infants or children underwent operation at our institution. Ten of them were treated with cardiac assist systems. Their ages ranged from 4 days to 8 years (median 5 months). In 8 patients we used a pulsatile circulatory support system available in 6 sizes (9, 10, 22.5, 25, 54, and 60 mL). A centrifugal pump was used in 2 additional infants. In 3 children cardiac assist was considered as a bridge to transplantation; in the remaining patients postcardiotomy failure or cardiogenic shock led to mechanical support. RESULTS: Median duration of assist was 4 days (range 8 hours to 17 days). In all cases we could observe recovery of renal, hepatic, and cardiac function in the immediate postimplantation period. Six patients survived and could be discharged either after successful transplantation or after myocardial recovery from postcardiotomy failure. The cause of death in 4 cases was bleeding and multiorgan failure. No technical failures occurred with either system. CONCLUSIONS: The pulsatile circulatory support system seems to be feasible and effective for pediatric extracorporeal support. If the anatomic situation does not permit implantation, centrifugal pumps are an alternative.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Sidiropoulos, H Hotz, W Konertz. 1998. Pediatric circulatory support.. https://pubmed.ncbi.nlm.nih.gov/9883757/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

3D heart model for computer simulations in cardiac surgery.

For a satisfactory computer simulation, a model, which imitates a natural situation, is needed. The Human heart is an irregular 3D object and thus difficult to reproduce. Basic data was taken from Visible Human Dataset (VHD), National Library of Medicine. The heart area was cut out of the original cross-sections and different tissues segmented. All the slices also had to be aligned to assure precise overlapping of the structures. A 3D computer heart model with the resolution of 1mm was designed. The heart model was dedicated to simulations of heat transfer during heart surgery however, it is applicable also to other medical simulations.

Cardiac Surgical Procedures↗