A statistically defined endpoint titer determination method for immunoassays.

Abstract

Results of immunoassays for which no positive standards are available are often expressed as endpoint titers. The endpoint titer is defined as the reciprocal of the highest analyte dilution that gives a reading above the cutoff. Unfortunately, there is no generally accepted rule for the determination of these cutoff values. In enzyme-linked immunosorbent assays (ELISA) a value two or three times the mean background or negative control reading is sometimes used. Other investigators set the cutoff arbitrarily at a certain absorbance value. These procedures do not provide statistically meaningful information about the risk of overtitration or false low titers. We have solved this problem by devising a practical method for establishing a statistically valid cutoff. The procedure involves calculating the upper prediction limit using the Student t-distribution. The mathematical formula which defines the upper prediction limit is expressed as the standard deviation multiplied by a factor which is based on the number of negative controls and the confidence level (1 - alpha). Appropriate factors are provided for 2 to 30 negative controls and for confidence levels ranging from 95% to 99.9%. Our new method is more reliable than other nonstatistical procedures yet does not require sophisticated computation. It can be applied to a variety of immunoassays provided that negative controls are available.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Frey, J Di Canzio, D Zurakowski. 1998-12-01. A statistically defined endpoint titer determination method for immunoassays.. https://doi.org/10.1016/s0022-1759(98)00170-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Recombinant truncated nucleocapsid protein as antigen in a novel immunoglobulin M capture enzyme-linked immunosorbent assay for diagnosis of severe acute respiratory syndrome coronavirus infection.

We report the development of an immunoglobulin M (IgM) antibody capture enzyme-linked immunosorbent assay (MAC-ELISA) for severe acute respiratory syndrome coronavirus (SARS-CoV) by using recombinant truncated SARS-CoV nucleocapsid protein as the antigen. The newly developed MAC-ELISA had a specificity and sensitivity of 100% as evaluated by using sera from healthy volunteers and patients with laboratory-confirmed SARS. Using serial serum samples collected from SARS patients, the times to seroconversion were determined by IgM antibody detection after SARS-CoV infection. The median time to seroconversion detection was 8 days (range, 5 to 17 days) after disease onset, and the seroconversion rates after the onset of illness were 33% by the first week, 97% by the second week, and 100% by the third week. Compared with the results of our previous report on the detection of IgG, the median seroconversion time by IgM detection was 3 days earlier and the seroconversion rate by the second week after the illness for IgM was significantly higher than by IgG assay. Our results indicating that the IgM response appears earlier than IgG after SARS-CoV infection in consistent with those for other pathogens. Our newly developed MAC-ELISA system offers a new alternative for the confirmation of SARS-CoV infection.

Enzyme-Linked Immunosorbent Assay↗

Perfusion with lipopolysaccharide differently affects the secretion of tumor necrosis factor-alpha and interleukin-6 by term and preterm human placenta.

This study has compared the functional capacity of term and preterm placentas in terms of production of pro-inflammatory cytokines in a perfusion system reflecting their ability to react to inflammatory agents, such as lipopolysaccharide (LPS), mimicking the situation of chorioamnionitis. We have demonstrated that term placentas secrete higher levels of tumor necrosis factor (TNF)-alpha compared with preterm placentas. Moreover, TNF-alpha secretion was significantly higher after exposure to LPS in the maternal and fetal sides of term placentas. In contrast, in preterm placentas, only the fetal side responded with a significant increase in secretion of TNF-alpha after exposure to LPS. The maternal side of term placentas secreted significantly higher amounts of interleukin (IL)-6 compared with preterm placentas. Exposure to LPS significantly decreased IL-6 secretion from the maternal side in both term and preterm placentas. Moreover, the fetal side of term placentas secreted significantly lower amounts of IL-6 compared with preterm placentas. In summary, this study has indicated that term and preterm placental tissues have a differing responsiveness to LPS stimulation, with term placentas disposed to a higher TNF-alpha:IL-6 ratio. Release of cytokines into fetal circulation is less than into the maternal side. However, TNF-alpha is released into fetal circulation after LPS stimulation and this may be relevant to the etiology of chorioamnionitis.

Enzyme-Linked Immunosorbent Assay↗